摘要
上海地球物理台站出现供电和仪器死机故障时,易出现数据断记,观测数据质量受到影响。针对此类故障,研发具备快速有效的自处置功能的台站电源监控系统。实际应用发现,数据断记时间有效减少,台站运行率和运行质量得到显著提升。
When power supply failure and instrument crashes occur at the Shanghai Geophysical Station,it is common to experience data interruptions that affect the quality of observation data.Aiming at such faults,a station power monitoring system was developed that has a fast and effective self-handling function.In practical applications,the duration of data interruptions was effectively reduced,and the operational efficiency and data qualityof station were significantly improved.
作者
裴晓
林航毅
PEI Xiao;LIN Hangyi(Shanghai Earthquake Agency,Shanghai 200062,China;Shanghai Sheshan National Geophysical Observatory,Shanghai 200062,China)
出处
《地震地磁观测与研究》
2023年第3期199-202,共4页
Seismological and Geomagnetic Observation and Research
基金
上海佘山地球物理国家野外科学观测研究站研究室课题任务(项目编号:2022SSY01)。
关键词
电源监控
自处置
移动终端
power monitoring
self-handling
mobile terminal