摘要
The laser-damage performance of optics is known to be negatively affected by microscale particle contamination induced by the operational environment.This work investigates the properties of particles accumulating in various locations near critical optics inside the OMEGA EP grating compressor chamber during quarterly operational periods over a 2-year duration.The particles found were characterized using optical microscopy,scanning electron microscopy and energy dispersive X-ray spectroscopy.The analysis indicates significant concentrations of micrometer-to nanometerscale particles inside the vacuum chamber,with higher values observed near the port leading to the OMEGA EP target chamber.The distribution of the chemical composition of these particles varies between collection periods.Although understanding of the mechanisms of particle generation and transport remains uncertain,the hypothesis is that this particle load represents a risk for contaminating the surfaces of high-value optics located inside the chamber,including the compression gratings and deformable mirrors,and therefore affecting their laser-damage resistance and overall operational lifetime.
基金
supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0003856
the University of Rochester
the New York State Energy Research and Development Authority
sponsored by an agency of the U.S