代表点法体源探测效率刻度研究

Efficiency Calibration of Volume Source with the Representative Point Method
下载PDF
导出
摘要 代表点法能在不受探测器内部结构和尺寸的影响下,实现高纯锗(HPGe)γ谱仪的快速效率刻度,简化传统地质和环境放射性样品核素分析过程。通过实验测量和蒙特卡罗模拟两种手段,对比研究其代表点位置求取的准确性,以证明代表点法在体源探测效率刻度工作中的可行性。结果表明,蒙特卡罗方法相较于传统的实验测量方法,代表点求取过程更加迅速,且同实验法计算的代表点位置基本接近。在不同测量高度下,代表点法计算出的土壤圆柱体源探测效率理论值与实验值的相对误差在5%之内,满足土壤圆柱体源探测效率刻度时不确定度的要求。 The representative point method can satisfy the rapid demanding for efficiency calibration of HPGe without influence of the detector structure and size,which simplify the nuclide analysis process of geological and environmental samples.However,this method is severally affected by the position accuracy and efficiency of representative point.The mathematical method was used to estimate the representative point position,which avoids the influence of radioactive source and detector.The accuracy and feasibility of the Monto Carlo method were analysed by comparing the representative point position between experimental results and Monto Carlo output.The practicable of the representative point method in body source detection efficiency calibration was analysed by comparing the detection efficiency of soil cylinder source and soil calibration source at different measuring heights.The Monto Carlo method is easier to calculate the representative points and approximate to the experimental results.At different measuring heights,the relative error of detection efficiency for the soil source between the representative point method results and the experiment conclusion is within 5%,which meets the requirement of uncertainty in soil source calibration.The internal size and structure of the detector have no influence on the location of the representative point.Therefore,the representative point method can realize the efficiency calibration for various body source,improve radionuclide analysis efficiency of geological and environmental samples.
作者 杨悦 熊川宝 刘文涛 YANG Yue;XIONG Chuan-bao;LIU Wen-tao(Physical and Chemical Analysis Test Center,Anhui Nuclear Exploration Technology Central Institute,Wuhu 641000,China)
出处 《核电子学与探测技术》 CAS 北大核心 2023年第2期301-306,共6页 Nuclear Electronics & Detection Technology
关键词 HPGE 有源无源结合效率刻度 代表点法 对比研究 核素分析 HPGe efficiency calibration combined with radioactive source and mathematical method representative point method comparative study nuclide analysis
  • 相关文献

参考文献4

二级参考文献31

  • 1王远大,朱树中,隆绍贤.参加环境放射性样品核素活度锗γ谱比对测量的总结[J].辐射防护,1994,14(5):358-365. 被引量:10
  • 2张斌全,马吉增,程建平,刘立业,毛永.蒙特卡罗方法计算用于低能光子测量的高纯锗探测器的效率[J].核电子学与探测技术,2005,25(3):274-277. 被引量:26
  • 3朱文凯,陈军,熊建平,陈坤,陈益军.ISOCS系统无源效率刻度测量方法的准确性检验[J].核电子学与探测技术,2005,25(3):287-290. 被引量:34
  • 4南亲良,硕士学位论文,1995年
  • 5杨伟,硕士学位论文,1990年
  • 6杨朝文,核技术,1988年,11卷,5期,37页
  • 7何宗慧,辐射防护,1987年,7卷,5期,167页
  • 8KARAMANIS D, LACOSTE V, ANDRI- AMONJE S, et al. Experimental and simulated efficiency of a HPGe detector with point-like and extended sources[J]. Nuclear Instruments and Methods in Physics Research A, 2002, 487(3): 477-487.
  • 9DEBERTINK, JIANGPING R. Measurement of the activity of radioactive samples in Marinelli heakers[J]. Nuclear Instruments and Methods in Physics Research A, 1989, 278(2): 541-549.
  • 10MOHAMMADI M A, ABDI M R, KAMALI M, et al. Evaluation of HPGe detector efficiency for point sources using virtual point detector model [J]. Applied Radiation and Isotopes, 2011, 69(2) : 521-526.

共引文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部