摘要
以兰州某机场为例,并结合实际工程机电设计,从供配电系统、照明系统、应急电源系统设计等方面出发,分析航站楼电气设计要点,探讨航站楼电气设计的最新动态。结果供同类项目参考。
Taking an airport in Lanzhou as an example,combined with the mechanical and electrical design of the actual project,from the aspects of power supply and distribution system,lighting system,emergency power supply system design,this paper analyzes the key points of the electrical design of the terminal,and discusses the latest trends of the electrical design of the terminal.It can provide reference for the electrical design of similar building in the future.
作者
秦国经
韩银凤
王超楠
郑欣
QIN Guojing;HAN Yinfeng;WANG Chaonan;ZHENG Xin(Northwest Company of China Construction Eighth Engineering Bureau Ltd.,Xi’an 710082,China)
出处
《现代建筑电气》
2023年第8期43-46,共4页
Modern Architecture Electric
关键词
航站楼
供电容量
自备应急电源
照明系统
terminal
power supply capacity
self provided emergency power supply
lighting