摘要 目前金精矿中全铁含量的测定标准方法为氯化亚锡还原-二氯化汞-重铬酸钾容量法,此法由于环保和试剂管控的要求给企业带来困扰。本文通过实验对比发现:三氯化钛还原-硫酸铜催化-重铬酸钾容量法相对于其他无汞法测定较为精准,同时探讨了此法的分解用酸、硅酸盐包裹消除、过量三氯化钛消除方式、干扰消除等问题,调整后方法相对标准偏差为0.13%~0.21%,准确度和精密度较高,且具有操作简单快速、成本低等优势,适合批量样品测定。 At present,the standard method for the determination of total iron content in gold concentrate is stannous chloride reduction-mercury chloride-potassium dichromate volumetric method.This method brings trouble to enterprises due to environmental protection and reagent control requirements.In this paper,through experimental comparison,it is found that the titanium trichloride reduction-copper sulfate catalysis-potassium dichromate volumetric method is more accurate than other mercury-free methods.At the same time,the problems of acid and silicate coating elimination,excessive titanium trichloride elimination method and interference elimination are discussed.After adjustment,the relative standard deviation of the method is 0.13%~0.21%,with high accuracy and precision,and it has the advantages of simple and fast operation and low cost,which is suitable for batch sample determination.
作者 余国尉 Yu Guowei(Jiangxi Sanhe Gold Industry Co.,Ltd.,Dexing 334200,China)
出处 《广东化工》 CAS 2023年第17期154-156,共3页 Guangdong Chemical Industry
关键词 金精矿 无汞法测铁 催化 干扰消除 重铬酸钾容量法 gold concentrate mercury-free iron measurement catalysis interference elimination potassium dichroite capacity method