摘要
针对传统的固定污染源烟气监测方法已无法达到国家有效标准的问题,本文结合实际案例改进了固定污染源烟气排放连续监测系统(CEMS)。经系统测试证明,改进后的CEMS系统更具准确性和可靠性。
Aiming at the problem that the traditional flue gas monitoring method for fixed pollution sources can no longer meet the effective national standards,this paper improves the continuous monitoring system(CEMS)for flue gas emissions from fixed pollution sources by combining with practical cases.The system test proved that the improved CEMS system is more accurate and reliable.
作者
张洋
贾旭光
卜令禹
董晓银
林泽惠
于艳娟
ZHANG Yang;JIA Xuguang;BU Lingyu;DONG Xiaoyin;LIN Zehui;YU Yanjuan(Xuzhou Inspection and Testing Center,Xuzhou,Jiangsu 221008,China;China University of Mining and Technology,Xuzhou,Jiangsu 221008,China)
出处
《自动化应用》
2023年第19期128-130,133,共4页
Automation Application