期刊文献+

Study of degradation of fuel cell stack based on the collected high-dimensional data and clustering algorithms calculations

原文传递
导出
摘要 Accurate perception of the performance degradation of fuel cell is very important to detect its health state.However,inconsistent operating conditions of fuel cell vehicles in the test result in errors in the data.In order to obtain a more credible degradation rate,this study proposes a novel method to classify the experimental data collected under different working conditions into similar operating conditions by using dimensionality reduction and clustering algorithms.Firstly,the experimental data collected from fuel cell vehicles belong to high-dimensional data.Then projecting high-dimensional data into three-dimensional feature vector space via principal component analysis(PCA).The dimension-reduced three-dimensional feature vectors are input into the clustering algorithm,such as K-means and density-based noise application spatial clustering(DBSCAN).According to the clustering results,the fuel cell voltage data with similar operating conditions can be classified.Finally,the selected voltage data can be used to precisely represent the true performance degradation of an on-board fuel cell stack.The results show that the voltage using the K-means algorithm declines the fastest,followed by the DBSCAN algorithm, finally the original data, which indicates that the performance of the fuel cell actually declines faste. Early intervention can prolong its life to the greatest extent.
出处 《Energy and AI》 2022年第4期29-40,共12页 能源与人工智能(英文)
基金 supported by the special key project of Chongqing technological innovation and application development(cstc2019jscx-zdztzxX0033) the national key R&D plan of the Ministry of science and Technology(sub project)(2018YFB0105400) the National Natural Science Foundation of China(21908142).

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部