摘要
变速抽水蓄能机组在电动状态下运行时,传统启动方式存在需要额外的启动装置,以及测速编码器会降低控制系统可靠性的问题。采用定子绕组短接的控制策略,实现了机组的自启动,避免附加设备的使用,节约机组建造成本;采用模型参考自适应算法,估算机组的转子转速和位置角,实现了无位置传感器控制。仿真结果表明,采用的自启动方案是有效、可行的,转速和位置角估计误差在可接受范围内。
When the variable speed pumped storage unit operates under electric state,there are problems that the traditional starting mode requires additional starting device,and the speed measuring encoder will reduce the reliability of the control system.In the paper,control strategy of stator winding short circuit was adopted to realize the selfstarting of the unit,avoid the use of additional equipment and save the construction cost of the unit;The model reference adaptive algorithm was used to estimate the rotor speed and position angle of the unit,and the sensorless control was realized.The simulation results show that the self-starting scheme is effective and feasible,and the estimation errors of speed and position angle are within the acceptable range.
作者
祝可可
阮琳
ZHU Ke-ke;RUAN Lin(Institute of Electrical Engineering,Chinese Academy of Sciences,Beijing 100190,China;University of Chinese Academy of Sciences,Beijing 100049,China)
出处
《计算机仿真》
北大核心
2023年第7期354-358,共5页
Computer Simulation
关键词
变速抽水蓄能机组
零速自启动
无速度传感器
模型参考自适应算法
波波夫超稳定性理论
Variable speed pumped storage unit
Zero-speed self-starting
Speed sensorless
Model reference adaptive algorithm
Popov theory of superstability