摘要
Current study deals with performance evaluation of the solar power tower driven recompression with main com-pressor intercooling(RMCIC)supercritical CO_(2)cycle incorporating the parallel double evaporator organic Rank-ine cycle(PDORC)as bottoming cycle using low global warming potential fluids to reduce the global warming and ozone depletion.Using the PDORC instead of the basic organic Rankine cycle,waste heat from the intercooler and cycle exhaust were recovered simultaneously to enhance performance of the standalone RMCIC cycle.Exergy,thermal efficiency,efficiency improvement and waste recovery ratio were considered as performance parameters.A computer program was made in engineering equation solver to simulate the model.It was concluded that by the incorporation of the PDORC thermal efficiency was improved by 7-8%at reference conditions.Maximum combined cycle’s thermal and exergy efficiency were found 54.42%and 80.39%respectively of 0.95 kW/m^(2)of solar irradiation based on R1243zf working fluid.Among the results it was also found that maximum waste heat was recovered by the R1243zf about 54.22%at 0.95 effectiveness of low temperature recuperator.