期刊文献+

超声检测胎儿MCA联合UA及右心室Tei指数诊断胎儿宫内缺氧效果 被引量:1

Diagnostic efficacy of the indexes values of fetal middle cerebral artery and umbilical artery examined by ultrasound combined with the fetal right ventricular myocardial performance index value for the fetal intrauterine hypoxia
下载PDF
导出
摘要 目的:探讨超声检测胎儿大脑中动脉(MCA)联合脐动脉(UA)及右心室心肌做功(Tei)指数诊断胎儿宫内缺氧的价值。方法:选择2020年1月-2022年12月在本院住院分娩的108例产妇临床资料,根据出生后胎儿是否发生宫内缺氧分为缺氧组(n=32)和正常组(n=76),记录产妇一般资料,彩色多普勒超声仪检测胎儿MCA、UA血流收缩期/舒张期(S/D)值、阻力指数(RI)和搏动指数(PI),右心室等容收缩时间(ICT)、等容舒张时间(IRT)和射血时间(ET),计算右心室Tei指数,Kappa一致性分析胎儿MCA、UA指标联合右心室Tei指数诊断胎儿宫内缺氧的价值。结果:缺氧组胎儿MCA的S/D值(3.27±0.88)、RI值(0.67±0.06)和PI值(1.58±0.39)均低于正常组(4.65±1.27、0.80±0.11、1.93±0.22),胎儿UA的S/D值(3.82±0.18)、RI值(0.86±0.21)和PI值(1.71±0.25)均高于正常组(2.54±0.31、0.63±0.17、0.95±0.22),胎儿右心室Tei指数(0.57±0.08)高于正常组(0.41±0.07)(均P<0.05)。MCA、UA指标联合右心室Tei指数诊断胎儿宫内缺氧的敏感度87.5%,特异度75.0%,Kappa值为0.550。结论:胎儿超声MCA联合UA及右心室Tei指数可提高诊断胎儿宫内缺氧的敏感度,一致性较高,可为临床诊断胎儿宫内缺氧提供参考指标。 Objective:To explore the diagnostic efficacy of the indexes values of fetal middle cerebral artery(MCA) and umbilical artery(UA) examined by ultrasound combined with the fetal right ventricular myocardial performance(Tei) index value for the fetal intrauterine hypoxia(FIH).Methods:The clinical data of 108 women who had delivered in hospital between January 2020 and December 2022 were selected in this study.According to presence or absence of FIH,the fetuses of these women were divided into study group(32 fetuses with FIH) and control group(76 fetuses without FIH).The general data of the women in the two groups were recorded.The values of MCA and UA indexes,such as peak systolic velocity/end diastolic velocity(S/D),and resistance index(RI),and pulsatility index(PI),and the values of the right ventricular isovolumetric contraction time(ICT),the isovolumic relaxation time(IRT),and the ejection time(ET) of the fetuses in the two groups were examined by color Doppler ultrasound.The right ventricular Tei index of the fetuses in the two groups was calculated.Kappa consistency analysis was used to analyze the value of the MCA and UA indexes combined with the right ventricular Tei index of the fetuses for diagnosing their FIH.Results:The values of S/D(3.27±0.88),RI(0.67±0.06),and PI(1.58±0.39) of MCA of the fetuses in the study group were significantly lower than those(4.65±1.27,0.80±0.11,and 1.93±0.22) of the fetuses in the control group.The values of S/D(3.82±0.18),RI(0.86±0.21),and PI(1.71±0.25) of UA of the fetuses in the study group were significantly higher than those(2.54±0.31,0.63±0.17,and 0.95±0.22) of the fetuses in the control group.The fetal right ventricular Tei index value(0.57±0.08) of the fetuses in the study group was significantly higher than that(0.41±0.07)of the fetuses in the control group(all P<0.05).The sensitivity and the specificity of the MCA and UA indexes combined with the right ventricular Tei index of the fetuses for diagnosing their FIH were87.5% and 75.0%,and Kappa value of which was 0.550.Conclusion:The indexes of fetal MCA and UA examined by ultrasound combined with the fetal right ventricular Tei index for diagnosing their FIH can improve the diagnostic sensitivity,with high consistency,and which can provide the reference indexes for the clinical diagnosis of FIH.
作者 傅国才 孙青 史丹丹 FU Guocai;SUN Qing;SHI Dandan(Jing County Hospital of Traditional Chinese Medicine,Xuancheng,Anhui Province,242500)
出处 《中国计划生育学杂志》 2023年第10期2439-2442,共4页 Chinese Journal of Family Planning
关键词 胎儿宫内缺氧 超声 大脑中动脉 脐动脉 右心室心肌做功指数 诊断 Fetal intrauterine hypoxia Ultrasound Middle cerebral artery Umbilical artery Right ventricular myocardial performance index Diagnosis
  • 相关文献

参考文献12

二级参考文献105

  • 1史美英.胎心监测联合脐血流S/D检测预测胎儿窘迫的价值评价[J].医学信息(医学与计算机应用),2014,0(13):423-423. 被引量:3
  • 2ACOG Committee Opinion. Number 326,December 2005. Inappropriate use of the terms fetal distress and birth as- phyxia[ J ]. Obstet Gyneco1,2005,106 ( 6 ) : 1469-1470.
  • 3Davies GA. Antenatal fetal assessment [ J ]. J Soc Obstet Gynaecol Can, 2000,22 ( 6 ) : 456-462.
  • 4Liston R, Sawchuck D, Young D. Fetal health surveil- lance: antepartum and intrapartum consensus guideline [ J ]. J Obstet Gynaeeol Can, 2007,29 ( 9 Suppl 4 ) : S3- S56.
  • 5Vintzileos AM, Gaffney SE, Salinger LM, et al. The rela- tionships among the fetal biophysical profile, umbilical cord pH, and Apgar scores [ J l. Am J Obstet Gynecol, 1987,157 ( 3 ) : 627-631.
  • 6Devoe LD, Jones CR. Nonstress test:evidence-based use in high-risk pregnancy[ J]. Clin Obstet Gynecol,2002,45 (4) :986-992.
  • 7Devoe LD. The nonstress test [ M ]//Eden RD, Boehm FH,eds. Assessment and care of the fetus: physiologic, clinical and medicolegal principles. East Norwalk:Apple- ton & Lange, 1990, pp 365-383.
  • 8Devoe LD. Antenatal fetal assessment:contraction stress test, nonstress test, vibroacoustic stimulation, amniotic flu- id volume, biophysical profile, and modified biophysical profile-an overview [ J ]. Semin Perinatol, 2008,32 : 247-252.
  • 9Freeman RK, Anderson G, Dorchester W. A prospective muhi-institutional study of antepartum fetal heart rate mo- nitoring. Ⅱ. Contraction stress test versus nonstress test for primary surveillance[ J ]. Am J Obstet Gynecol, 1982, 143(7) :778-781.
  • 10Manning FA. Dynamic ultrasound-based fetal assessment: the fetal biophysical profile score [ J ]. Clin Obstet Gyne- col, 1995,38 ( 1 ) :26-44.

共引文献210

同被引文献16

引证文献1

相关作者