摘要
在大型封闭储煤场室内自动消防炮设计中,布置在马道上的自动消防炮主要受煤堆垛及屋面遮挡影响,设计最大保护半径受到抑制,相关规范及文献缺少应对措施。以内蒙古自治区某地一座20万t储量的封闭室内储煤场为例,研究煤堆垛及屋面对自动消防炮设计的影响及其应对方法。首先,利用自动消防炮火源探测器视角及射流轨迹特点,选定自动消防炮在建筑宽度方向最佳布置区域及高度范围;其次,依据自动消防炮设计最大保护半径,确定其在建筑长度方向的最佳布置位置;然后,以0°角喷射的射流轨迹复核自动消防炮在该平面位置及高度上的实际保护范围,最终消除煤堆垛及屋面对自动消防炮的遮挡影响。
In the design of automatic fire monitor system in large⁃scale closed coal storage yards,the automatic fire monitors ar⁃ranged on the horse road are mainly affected by coal stacking and roof,and the design maximum protection radius is suppressed.But the relevant standards and literature lack corresponding coun⁃termeasures.Taking an example of a closed coal storage yard with 200,000 t of reserves in a certain place in Inner Mongolia,the influences of coal stacking and roof on the automatic fire moni⁃tors and countermeasures were studied.Firstly,the viewing angles of fire source detector in automatic fire monitor and jet tra⁃jectory characteristics were utilized to select the optimal layout area and height range of the automatic fire monitors in the direc⁃tion of building width.Then,according to the maximum protec⁃tion radius of the automatic fire monitor,determined the best posi⁃tion in the direction of building length.After that,the actual pro⁃tective range of the automatic fire monitors was reviewed with the jet trajectory sprayed at an angle of 0°.Finally,the influences of coal stacking and roof on the automatic fire monitors were elimi⁃nated.
作者
胡纯国
徐力
Hu Chunguo;Xu Li(Dalian Port Design&Research Institute Co.,Ltd.,Liaon-ing Dalian 116006,China)
出处
《消防科学与技术》
CAS
北大核心
2023年第10期1423-1427,共5页
Fire Science and Technology
关键词
自动消防炮
封闭储煤场
煤堆垛
屋面
遮挡
automatic fire monitor
closed coal storage yard
coal stacking
roof
shelter