摘要 目的建立石墨炉原子吸收光谱法(AAS)测定透析用盐类药用辅料中铝元素的含量。方法样品加硝酸超声处理,采用铝空心阴极灯,波长:309.3 nm,电流:15 mA,光谱狭缝宽度:0.5 nm,塞曼偏振背景校正,基体改进剂:0.1%硝酸镁,进样测定,采用外标法计算。结果铝离子在5~40 ng·mL^(-1)内与响应值线性关系良好(r=0.9995);检测限为1 ng·mL^(-1);乳酸钠、氯化钙、醋酸钠、氯化钾、氯化镁、氯化钠中铝平均回收率在81.8%~98.4%。结论本方法准确度高、重现性好,可用于透析用盐类药用辅料中铝元素的含量测定。 Objective To determine the content of aluminum in salt pharmaceutical excipients for dialysis by graphite furnace atomic absorption spectrometry(AAS).Methods The samples with nitric acid were ultrasonically treated,aluminum hollow cathode lamp was used.The measurement wavelength was 309.3 nm,the current was 15 mA,the spectral slit width was 0.5 nm,and the Zeeman polarization background was corrected.The matrix improver was 0.1%magnesium nitrate,measured and calculated with external standard method.Results The linearity was good in the concentration range of 5~40 ng·mL^(-1)(r=0.9995).The detection limit was 1 ng·mL^(-1).The average recovery of aluminum in sodium lactate,calcium chloride,sodium acetate,potassium chloride,magnesium chloride,and sodium chloride was between 81.8%and 98.4%.Conclusion The method is highly accurate and reproducible,and can be used for the determination of aluminum content in salt pharmaceutical excipients for dialysis.
作者 张悦 谢莹莹 ZHANG Yue;XIE Ying-ying(Hunan Institute for Drug Control,Changsha 410001;Hunan Drug Inspection Center,Changsha 410001;NMPA Key Laboratory for Pharmaceutical Excipients Engineering Technology Research,Changsha 410001)
出处 《中南药学》 2023年第10期2724-2728,共5页 Central South Pharmacy
基金 湖南省自然科学基金科药联合基金项目(No.2022JJ80013)。
关键词 石墨炉原子吸收光谱法 透析液 药用辅料 graphite furnace atomic absorption spectrometry dialysis aluminum pharmaceutical excipient
  • 相关文献

参考文献8

二级参考文献67

共引文献30

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部