某立式循环水泵电机轴承异常振动分析与处理

Analysis and Treatment on Abnormal Vibration of a Vertical Circulating Water Pump Motor Bearing
下载PDF
导出
摘要 采用振动测试仪对某立式循环水泵电机轴承进行振动测试,获取了轴承的振动特征。根据振动特征,逐步排查故障原因,并确定电机轴承振动超标的原因是循环水泵下导轴承磨损。最终,通过更换下导轴承并严格控制安装参数,将电机轴承的振动降低到合格水平,保证了设备的长期安全运行。 The vibration test of a vertical circulating water pump motor bearing is carried out by using a vibration tester and the vibration characteristic of the bearing is obtained.According to the vibration characteristics,the cause of the fault is gradually investigated,and it is determined that the cause of the excessive vibration of the motor bearing is the wear of the lower guide bearing of the circulating water pump.Finally,the vibration of the motor bearing is reduced to a qualified level,by means of replacing the lower guide bearing and strictly controlling the installation parameters,ensuring the long-term safe operation of the equipment.
作者 宋亚军 杨环宇 蓝天来 王维萌 SONG Yajun;YANG Huanyu;LAN Tianlai;WANG Weimeng(State Grid Jibei Electric Power Co.Ltd.Research Institute,100045;Beijing Jingfeng Gas Turbine Power Co.,Ltd.,100074;Beijing Jingxi Gas-fired Thermal Power Co.,Ltd.,100041)
出处 《电机技术》 2023年第5期54-57,共4页 Electrical Machinery Technology
关键词 立式 循环水泵 电机 振动 vertical circulating water pump motor vibration
  • 相关文献

参考文献3

二级参考文献7

  • 1长沙水泵厂.56LKSB-25型泵安装使用说明书.
  • 2化工部.HGJ203-83,化工机器安装施工及验收规范[S].
  • 3国家电力公司规划设计总院.DLGJ150-1999火力发电厂循环水泵房进水流道及其布置设计技术规定[S].北京:国家电力公司中南电力设计院,1999.
  • 4赵祝人,徐云泉,余晓明,等.电力建设施工技术规范第3部分.汽轮发电机组[M].北京:中国电力出版社,2012:156-167.
  • 5鲁焕浩,俞杏梅,王伟民,等.电力建设施工质量验收及评价规程第3部分汽轮发电机组[M].北京:中国电力出版社,2009:158-163.
  • 6吕鹏飞.循环水泵电机冷却水阀门检修[J].华电技术,2010,32(3):62-63. 被引量:4
  • 7鲍金春.循环水泵双速电机的节能改造[J].华电技术,2011,33(9):59-60. 被引量:9