摘要 为探讨数据中心混合冷却系统的节能应用,采取创新性的改造策略,在保留原有设备的基础上,将现有的服务器模块整合并密封于液冷模块中,通过电子氟化液半浸没式冷却实现直接高效冷却。同时,优化冷却系统的配置,引入改造冰柜以适应夏季高温和平滑电网负荷;还采用高效风墙对大型塔式设备和低能耗设备进行集中散热。结果显示,混合冷却系统显著提高了数据中心的冷却效率和能源利用率,展现出卓越的性能和实用性。 In order to explore the energy-saving application of hybrid cooling systems in data centers,an innovative transformation strategy is adopted.On the basis of retaining the original equipment,the existing server modules are integrated and sealed in liquid cooling modules,and the direct and efficient cooling is achieved through the semi-immersed cooling of electronic fluorinated liquid.At the same time,the configuration of the cooling system is optimized,and the modified freezer is introduced to adapt to the high temperature and smooth grid load in summer;high-efficiency wind walls are also used to centrally dissipate heat for large tower equipment and low-energy consumption equipment.The results show that the hybrid cooling system significantly improves the cooling efficiency and energy utilization of the data center,demonstrating excellent performance and practicality.
作者 郑亮 郑洪斌 陈以乐 黄林生 ZHENG Liang;ZHENG Hongbin;CHEN Yile;HUANG Linsheng(Faculty of Humanities and Arts,Macao University of Science and Technology,Macao 999078,China;Guangzhou Zhiguang Information Technology Co.,Ltd.,Guangzhou Guangdong 510425,China;School of Civil Engineering,Putian University,Putian Fujian 351100,China)
出处 《莆田学院学报》 2023年第5期94-101,共8页 Journal of putian University
基金 福建省自然科学基金资助项目(2023J011001)。
关键词 数据中心 混合冷却系统 节能策略 data center hybrid cooling system energy saving strategy
  • 相关文献

参考文献7

二级参考文献88

共引文献58

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部