摘要 针对糠醛试验检测无法完全准确地反映变压器老化情况,提出一种基于绝缘纸聚合度预测评估变压器老化的方法。笔者分析了绝缘纸老化与绝缘纸聚合度、糠醛含量之间的关系,研究了绝缘纸聚合度预测方法,并将该方法应用于天生桥一级水电站变压器绝缘纸老化预测。结果表明,采用修正的绝缘纸聚合度预测公式可合理预测聚合度值,据该值计算糠醛含量,进而评估变压器老化情况。该方法可推广应用于同类型变压器寿命预测。 In view of the fact that furfural test can not fully and accurately reflect the aging of transformer,a method based on the polymerization degree prediction of insulating paper is proposed to evaluate the aging of transformer.By analyzing the theoretical relationship between the insulating paper aging and the degree of polymerization of insulating paper and furfural content,the prediction formula of the degree of polymerization of insulating paper is modified and the degree of polymerization is reasonably predicted.Based on this,the furfural content is calculated,and then the aging of transformer is evaluated.The method proposed in this paper can also be applied to the life prediction of similar oil immersed transformers.
作者 陈钰林 许再尧 莫元雄 程国莉 范志鹏 CHEN Yulin;XU Zaiyao;MO Yuanxiong;CHENG Guoli;FAN Zhipeng(Guangdong Energy Group TianshengqiaoⅠHydropower Development Co.,Ltd.,Hydropower Plant,Xingyi 562400,China)
出处 《红水河》 2023年第5期107-111,共5页 Hongshui River
关键词 糠醛 油浸式变压器 绝缘纸 聚合度 老化 furfural oil immersed transformer insulating paperr degree of polymerization ageing
  • 相关文献

参考文献7

二级参考文献86

  • 1杨丽君,廖瑞金,孙才新,李剑,梁帅伟.油纸绝缘老化阶段的多元统计分析[J].中国电机工程学报,2005,25(18):151-156. 被引量:34
  • 2李晓虎,李剑,杜林,杨丽君,孙才新.一种转基因菜籽绝缘油的电气性能[J].中国电机工程学报,2006,26(15):95-99. 被引量:41
  • 3李晓虎,李剑,孙才新,党剑亮,李勇.植物油-纸绝缘的电老化寿命试验研究[J].中国电机工程学报,2007,27(9):18-22. 被引量:37
  • 4Unsworth J, Mitchell F. Degradation of electrical insulating paper monitored with high performance liquid chromatography[J]. IEEE Trans. Elect. Insul, 1990,25(4):737-746.
  • 5U GAFVERT, G FRIMPONG, J FUHR. Modelling of Dielectric Measurements on Power Transforms[ C ]. Paris : CIGRE, 1998.
  • 6S M GUBANSKI, P Boss. Dielectric Response Methods for Diagnostics of Power Transformers[ J ]. IEEE, 2003, 19(3) : 12-18.
  • 7Oommen T V. Vegetable oils for liquid-filled transformers[J]. IEEE Electrical lnsulationMagazine, 2002, 18(1): 6-11.
  • 8Prevost TA. Thermally upgraded insulation in transformers[C]. Electrical Insulation Conference and Electrical Manufacturing Expo, Indianapolis, 2005.
  • 9Yamagata N, Miyagi K, Oe E. Diagnosis of thermal degradation for thermally upgraded paper in mineral oil[C]. 2008 International Conference on Condition Monitoring and Diagnosis, Beijing, 2008.
  • 10Fofana I, Wasserberg V, Borsi H, et al. Challenge of mixed insulating liquids for use in high-voltage transformers, part 2: investigations of mixed liquid impregnated paper insulation[J]. IEEE Electrical Insulation Magazine, 2002, 18(4): 5-16.

共引文献139

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部