双面屏蔽防护在心脏冠状动脉CT血管成像检查中的辐射防护优化价值

Optimization Value of Double-sided Shielding in Radiation Protection of Cardiac Coronary Artery CT Angiography
下载PDF
导出
摘要 目的探讨胸腹前、后非照射部位双面屏蔽防护在心脏冠状动脉CT血管成像(CCTA)检查中的辐射防护优化价值。方法用胸部模型模拟CCTA检查,前瞻性研究胸部模型检查区和检查区之外邻近非检查区分别在胸腹前单面屏蔽防护(单面防护组)以及胸腹前、后双面屏蔽防护(双面防护组)条件下体表(设定测试点并放置热释光剂量计)辐射剂量并进行统计学分析。单面防护组和双面防护组采用相同CCTA技术条件扫描,测试点的辐射剂量由热释光读出器读出辐射剂量当量数值。结果双面防护组CCTA受检者(胸部体模替代)上部非检查区体表测试点(R 3、L 4~6、R 7~9)辐射剂量当量小于单面防护组[(0.730±0.001)mSv比(1.090±0.005)mSv、(1.260±0.002)mSv比(1.610±0.005)mSv、(0.690±0.001)mSv比(0.960±0.009)mSv、(0.839±0.002)mSv比(1.340±0.001)mSv、(0.820±0.009)mSv比(1.009±0.015)mSv、(0.720±0.002)mSv比(0.910±0.008)mSv、(0.350±0.062)mSv比(0.672±0.079)mSv](P<0.05或P<0.01),下部非检查区体表测试点(R 10、L 11~13、R 14~15、X 16)辐射剂量当量小于单面防护组[(0.770±0.002)mSv比(1.230±0.003)mSv、(0.920±0.002)mSv比(1.200±0.004)mSv、(1.090±0.001)mSv比(1.353±0.036)mSv、(0.770±0.002)mSv比(1.360±0.004)mSv、(0.510±0.006)mSv比(0.990±0.000)mSv、(0.570±0.001)mSv比(0.700±0.008)mSv、(0.040±0.002)mSv比(0.080±0.005)mSv](P<0.05或P<0.01),整体测试点辐射剂量当量小于单面防护组(P<0.01)。两组CCTA受检者检查区体表测试点R 1、L 2及整体测试点体表辐射剂量当量比较差异无统计学意义(P>0.05)。结论与胸腹前单面屏蔽防护方式相比,胸腹前、后双面屏蔽防护方式对CCTA的辐射防护更具优化价值。 Objective To discuss the value of double-sided shielding of front and back non-irradiation areas of chest and abdomen in optimizing the radiation protection of cardiac coronary artery CT angiography(CCTA).Methods The chest model was used to simulate CCTA examination,and the radiation dose of the body surface(test points were set and thermoluminescent dosimeter was placed)was prospectively studied in the chest model examination area and the adjacent non-examination area under the conditions of chest and abdomen front single-sided shield protection(single-sided shield group)and chest and abdomen front and back double-sided shield protection(double-sided shield group),respectively,and statistical analysis was conducted.The single-side protection group and double-side protection group were scanned by the same CCTA technology,and the radiation dose equivalent at test points was read out by thermoluminescent reader.Results The radiation dose equivalent of the body surface test points(R 3,L 4-6,R 7-9)in the upper non-examination area of CCTA subjects(chest body model replacement)in the double-sided protection group were lower than those in the single-sided protection group[(0.730±0.001)mSv vs(1.090±0.005)mSv,(1.260±0.002)mSv vs(1.610±0.005)mSv,(0.690±0.001)mSv vs(0.960±0.009)mSv,(0.839±0.002)mSv vs(1.340±0.001)mSv,(0.820±0.009)mSv vs(1.009±0.015)mSv,(0.720±0.002)mSv vs(0.910±0.008)mSv,(0.350±0.062)mSv vs(0.672±0.079)mSv](P<0.05 or P<0.01).The radiation dose equivalent of the body surface test points(R 10,L 11-13,R 14-15,X 16)in the lower non-examination area were less than those of the single-sided protection group[(0.770±0.002)mSv vs(1.230±0.003)mSv,(0.920±0.002)mSv vs(1.200±0.004)mSv,(1.090±0.001)mSv vs(1.353±0.036)mSv,(0.770±0.002)mSv vs(1.360±0.004)mSv,(0.510±0.006)mSv vs(0.990±0.000)mSv,(0.570±0.001)mSv vs(0.700±0.008)mSv,(0.040±0.002)mSv vs(0.080±0.005)mSv](P<0.05 or P<0.01),and the radiation dose equivalent of the overall test points was less than that of the single-sided protection group(P<0.01).There was no significant difference in body surface radiation dose equivalent between the two groups at the body surface test points R 1,L 2 and the whole test point in the examination area of CCTA subjects(P>0.05).Conclusion Compared with the chest and abdomen front single-sided shield,the chest and abdomen front and back double-sided shield has more optimization value for radiation protection of CCTA.
作者 张立新 吴柯薇 李向明 钟朝晖 杨正汉 孔亚群 王新明 ZHANG Lixin;WU Kewei;LI Xiangming;ZHONG Zhaohui;YANG Zhenghan;KONG Yaqun;WANG Xinming(Department of Radiology,Capital Medical University,Beijing 101100,China;Department of Stomatology,Beijing Friendship Hospital,Capital Medical University,Beijing 101100,China;Radiation Health Protection Institute,Beijing Center for Disease Control and Prevention,Beijing 100013,China;Beijing Betterbury Technology Testing Co.,Ltd.,Beijing 100000,China)
出处 《医学综述》 CAS 2023年第8期1645-1650,共6页 Medical Recapitulate
基金 北京市医院管理中心临床医学发展专项“扬帆”计划(重点培育专业)(ZYLX202101)。
关键词 心脏冠状动脉CT血管成像 胸部模型 热释光剂量计 辐射剂量当量 胸腹前、后双面屏蔽防护 胸腹前单面屏蔽防护 检查区 非检查区 Cardiac coronary artery CT angiography Chest model Thermoluminescent dosimeters Radiation dose equivalent Double-sided shielding protection in front and back of chest and abdomen Single-sided shielding protection in front of chest and abdomen Examination area Non-examination area
  • 相关文献

参考文献21

二级参考文献158

共引文献331

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部