期刊文献+

基于FPGA的远距离单光子精细化时间数字转换电路

Long distance single photon precision time digital conversion circuit based on FPGA
下载PDF
导出
摘要 针对星载GM-APD单光子测距系统难以兼顾宽量程高精度测量问题,文中设计了一种基于等效脉冲粗精两级的精细化时间数字转换电路(Time-to-Digital Converter,TDC)。该TDC首先基于分段式计数原理,设计了粗精两级的计数架构,保证了TDC宽量程测量;其次,针对精计数单元,采用时钟等相差相移π/N,生成等效高频脉冲时钟,将精计数单元的计时精度提升N倍;再次采用多计数器双沿间隔计数方法,将精计数单元计时精度进一步提升至2N倍;最后通过模拟仿真与实验验证对文中设计的TDC进行远距离单光子测距性能测试。仿真与实验结果表明:文中面向远距离单光子测距设计的精细化时间数字转换电路在参考时钟为50 MHz时,计时分辨率为416.67 ps,计时量程达1.31 ms。对室内10 m处目标进行100次测距重复实验,测距误差为5.62 cm,对室外参考距离为2616.5 m处目标进行测距实验,测距的方差为0.0017 m,由此可见,基于文中等效脉冲粗精两级精细化时间数字转换电路的单光子测距系统可以实现远距离目标的高精度、宽量程测量。 Objective Single photon ranging system is a system that uses the photon level detection sensitivity of GM-APD detector and obtains the distance information of far-field target based on the principle of photon time-of-flight ranging.The system has the advantages of long range and high ranging accuracy,and has great application potential in laser imaging,target detection and other fields.As the core module of single photon ranging system,the range and accuracy of time digital conversion circuit directly determine the working range and ranging accuracy of the ranging system.And in the field of spaceborne detection,the ranging system is required to have the ranging range of more than 100 km and centimeter-level ranging accuracy.At this time,the traditional time digital conversion circuit,limited by the counter number,in order to ensure the ranging accuracy,often lead to the limited system's measuring range,and if the system's range is increased,the system's ranging accuracy is difficult to meet the needs.In this paper,a time digital conversion circuit satisfying both wide range and high precision is designed to realize the wide range and high precision measurement of photon flight time interval.It provides technical support for single photon ranging in the field of spaceborne laser detection.Methods In order to solve the contradiction between wide range and high precision,a refined time digital conversion circuit design method for long-distance single photon ranging is proposed.Firstly,based on the piecewise counting principle,a coarse and fine two-stage counting architecture is designed to ensure the wide range measurement of TDC(Fig.5,Fig.10).Secondly,for the fine counting unit,the clock equal phase shiftπ/N is used to generate an equivalent high-frequency pulse clock(Fig.6),which improves the timing accuracy of the fine counting unit by N times.The timing accuracy of the fine counting unit was further improved to 2N times by using the multi-counter double-edge interval counting method(Fig.7).Results and Discussions Vivado software was used to verify the accuracy and range of the proposed algorithm,and the simulation results of the accuracy(Fig.11)and range(Fig.12)were given.In order to further verify the performance of GM-APD laser ranging system designed in this paper based on equivalent pulse two-stage time digital conversion circuit,the indoor and outdoor ranging experiments were carried out respectively,and the indoor ranging results(Tab.1)and outdoor ranging results(Fig.16-17,Tab.3)were given.The experimental results show that the coarse and fine two-stage counting system can effectively reduce the limit of TDC timing accuracy to its range.The timing resolution of TDC is 416.67 ps,and the ranging range is 196.608 km,which solves the contradiction between wide range and high precision.Conclusions A fine time digital conversion circuit for distance single photon ranging is designed,and a TDC module with high precision,high stability and easy to expand is implemented on FPGA.By using the TDC design method of coarse and fine two-stage counting,the clock signal of the same frequency phase shift and equal phase difference,and the two-side edge precision time counting,the wide range and high precision measurement of photon flight time are realized.The structure of the proposed refined time digital converter circuit is relatively simple and flexible.The number of counter bits is 16 and the number of clocks with equal phase shift in the same frequency is 6.The range and timing accuracy of TDC conversion can be further improved by increasing the number of counter bits and the number of clocks with phase shift.
作者 谢达 王春阳 袁凯 卫旭阳 刘雪莲 Xie Da;Wang Chunyang;Yuan Kai;Wei Xuyang;Liu Xuelian(School of Electronic and Information Engineering,Changchun University of Science and Technology,Changchun 130022,China;Xi'an Key Laboratory of Active Photoelectric Imaging Detection Technology,Xi'an Technological University,Xi'an 710021,China)
出处 《红外与激光工程》 EI CSCD 北大核心 2023年第10期247-257,共11页 Infrared and Laser Engineering
基金 国家重点研发计划项目(2022YFC3803702)。
关键词 单光子 激光测距 时间数字转换 等效脉冲 GM-APD single photon laser ranging time digital conversion equivalent pulse GM-APD
  • 相关文献

参考文献16

二级参考文献139

  • 1郭金权,李国元(指导),左志强,张宁,裴亮,卢刚.高分七号卫星激光测高仪全波形数据质量及特征分析[J].红外与激光工程,2020,49(S02):137-146. 被引量:4
  • 2CAI ZhanChuan1,2,ZHENG CaiMu1,2,TANG ZeSheng1,2,3 & QI DongXu1,2,4 1 Faculty of Information Technology,Macao University of Science and Technology,Macao,China,2 Collaborative Research Laboratory on Lunar and Planetary Exploration,Macao University of Science and Technology,Macao,China,3 School of Information Science and Technology,Tsinghua University,Beijing 100084,China,4 School of Information Science and Technology,Sun Yat-sen University,Guangzhou 510275,China.Lunar digital elevation model and elevation distribution model based on Chang’E-1 LAM data[J].Science China(Technological Sciences),2010,53(9):2558-2568. 被引量:4
  • 3庞勇,孙国清,李增元.林木空间格局对大光斑激光雷达波形的影响模拟[J].遥感学报,2006,10(1):97-103. 被引量:24
  • 4李勇,苏弘,千奕,李素琴,彭宇,李小刚.多道时间幅度变换电路的设计[J].核电子学与探测技术,2006,26(4):454-457. 被引量:3
  • 5Albota M A, He inrichs R M, Kocher D G. Three?dimensional imaging laser radar with a photon-counting avalanche photodiode array and microchip laser[J]. Appl Opt, 2002, 41: 7671-7678.
  • 6Massa J S, Wallace AM, Buller G S. Laser depth measurement based on time-correlated single-photon counting[J]. Opt Lett, 1997, 22: 543-545.
  • 7Fouche Daniel G. Detection and false-alarm probabilities for laser radars that use Geiger-mode detectors[J]. Appl Opt, 2003, 42: 5388-5398.
  • 8Wang Fei, Zhao Yuan, Zhang Yu. Range accuracy limitation of pulse ranging systems based on Geiger mode single?photon detectors[J]. Appl Opt, 2010, 49: 5561-5566.
  • 9Hong Jin Kong, Tae Hoon Kim, Sung Eun Jo. Smart three?dimensional imaging ladar using two Geiger-mode avalanche photodiodes[J]. Opt Express, 2011, 19: 19323-19329.
  • 10Philip Gatt, Steven Johnson, Terry Nichols. Geiger -mode avalanche photodiode ladar receiver performance characteristics and detection statistics[J]. Appl Opt, 2009, 48: 3261-3276.

共引文献109

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部