二次谐波分量下锂离子电池安全运行区间研究

STUDY ON SAFE OPERATION RANGE OF LITHIUM-ION BATTERY UNDER SECOND HARMONIC COMPONENT
下载PDF
导出
摘要 针对光储系统直流侧主要二次谐波分量对储能电池影响的问题,该文通过电化学模型分析直流侧不同大小的二次谐波分量对锂离子电池内外特性影响的机理和规律,发现影响电池寿命的主要因素是电池充放电状态期间的电流平均值而不是电流有效值。根据该因素对电池寿命的影响程度提出可将电流中二次谐波分量大小分为3个区间,相对应分为不显著影响电池寿命、减缓电池寿命衰减及加速电池寿命衰减,最后通过仿真以及实验验证了这3个区间,基于这3个区间可为工程应用中优化光储系统与电网交互影响下锂离子电池安全运行区间提供参考,降低储能直流侧滤波器成本。 For the main second harmonic component of the DC side of the photovoltaic storage system on the impact of energy storage batteries,the paper analyzes the mechanism and law of the influence of different sizes of second harmonic components on the internal and external characteristics of the Li-ion battery through electrochemical modeling,and finds that the main factor affecting the battery life is the average value of the current during the charging and discharging state rather than the effective value of the current.Based on the influence of this factor on the battery life,it is proposed that the second harmonic component of current can be divided into three intervals,which are not significantly affecting the battery life,slowing down the battery life decay and accelerating the battery life decay,and finally these three intervals are verified by simulation and experiment.These three intervals provide a reference for optimizing the safe operation interval of lithium-ion batteries under the influence of interaction between photovoltaic storage system and power grid in engineering applications and reducing the cost of DC-side filters for energy storage.
作者 夏向阳 陈贵全 夏天 周冠东 欧名勇 王灿 Xia Xiangyang;Chen Guiquan;Xia Tian;Zhou Guandong;Ou Mingyong;Wang Can(School of Electrical and Information Engineering,Changsha University of Science and Technology,Changsha 410114,China;State Grid Hunan Electric Power Company,Changsha 410004,China;Economic and Technological Research Institute of State Grid Hunan Electric Power Company,Changsha 410004,China;Changgao Electric Group Co.,Ltd.,Changsha 410219,China)
出处 《太阳能学报》 EI CAS CSCD 北大核心 2023年第10期496-503,共8页 Acta Energiae Solaris Sinica
基金 国家自然科学基金(51977014) 国网湖南省电力有限公司科技项目(5216A220000X) 湖南省研究生科研创新项目(CX20210793) 智慧型高压开关物联网技术应用研究与产业化(kh2205010)。
关键词 光伏发电 电池储能系统 谐波分析 锂离子电池 电池内外特性 电化学 安全运行区间 PV power battery energy storage system harmonic analysis lithium-ion batteries internal and external characteristics of battery electrochemistry safe operation interval
  • 相关文献

参考文献6

二级参考文献88

  • 1王守相,黄丽娟,王成山,李东.分布式发电系统的不平衡三相潮流计算[J].电力自动化设备,2007,27(8):11-15. 被引量:101
  • 2鲁宗相,王彩霞,闵勇,周双喜,吕金祥,王云波.微电网研究综述[J].电力系统自动化,2007,31(19):100-107. 被引量:932
  • 3Tonkoski, Reinaldo,Lopes, Luiz A. C.,El-Fouly, Tarek H. M.Coordinated active power curtailment of grid connected PV inverters for overvoltage prevention. IEEE Transactions on Sustainable Energy . 2011
  • 4Ying Jiang,Jianguo Li,Sanbo Pan,Xi Zhang,Peng Hu,Haiyan Zhang,Keith Emery.??Research on the Comparison Analyses of Three-Phase Discrete and Integrated LC Filters in Three-Phase PV Inverter(J)International Journal of Photoenergy . 2013
  • 5S. Reber,A. Hurrle,A. Eyer,G. Willeke.??Crystalline silicon thin-film solar cells—recent results at Fraunhofer ISE(J)Solar Energy . 2004 (6)
  • 6S. Conti,A. Greco.Local Voltage Regulation in LV Distribution Network with PVDistributed Generation. International Symposium on Power Electronics,Electrical Drives, Automation and Motion . 2006
  • 7Canova, Aldo,Giaccone, Luca,Spertino, Filippo,Tartaglia, Michele.Electrical impact of photovoltaic plant in distributed network. IEEE Transactions on Industry Applications . 2009
  • 8傅闯,饶宏,黎小林.交直流混合电网中直流50Hz和100Hz保护研究[J].电力系统自动化,2008,32(12):57-60. 被引量:45
  • 9朱韬析,武诚,王超.交流系统故障对直流输电系统的影响及改进建议[J].电力系统自动化,2009,33(1):93-98. 被引量:43
  • 10杨旭英,段建东,杨文宇,杨俊杰,王森.含分布式发电的配电网潮流计算[J].电网技术,2009,33(18):139-143. 被引量:58

共引文献52

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部