摘要
通过在主反应区增设搅拌器,考察生化池在闲置/进水阶段在增加搅拌的作用下的处理效果,结果表明,增加搅拌60 min的TN、TP的平均去除率分别为59%、94%,脱氮除磷效果最好,可优于提标改造后的一级A工艺出水水质,并且去除率在第10 d后开始趋向稳定,出水都达到一级A标准要求。本研究为相关污水处理厂优化调控,低碳运营,提供了可供借鉴、参考的案例。
Through installing agitator in the main reaction zone,to investigate the treatment effect of the biochemical pool under the effect of increasing agitation in idle/influent stage.The results showed that the removal rate of pollutants can be better than that of grade a process after upgrading,and after stirring for 60 minutes,the average removal rate of TN and TP was 59%and 94%,respectively,which the effect of nitrogen and phosphorus removal was the best.The removal rate tended to be stable after the 10th day,and the effluent reached the requirements of grade A standard.This study provides a reference case for optimizing regulation and low-carbon operation of relevant sewage treatment plants.
作者
何智丽
李静
蔡坤河
莫幼轩
冉冬梅
王鹏
梁玉炫
He Zhili;Li Jing;Cai Kunhe;Mo Youxuan;Ran Dongmei;Wang Peng;Liang Yuxuan(Dongguan Shigu Sewage Treatment Co.,Ltd.,Dongguan 523591;Dongguan Cleaner Production Center,Dongguan 523808;Guangdong Huaqing Detection Technology Co.,Ltd.,Dongguan 523808,China)
出处
《广东化工》
CAS
2023年第20期133-137,共5页
Guangdong Chemical Industry
基金
2023年东莞市社会发展科技面上项目(20231800939642)。
关键词
污水处理厂
提标改造
一级A
标准运行优化
全流程分析
sewage treatment plant
upgrading and reconstruction
level A standard
standard operation optimization
full process analysis