期刊文献+

骨细胞方向对负荷诱导的骨内液体流动和营养物质运输的影响

Effects of osteocyte orientation on loading-induced interstitial fluid flow and nutrient transport in bone
原文传递
导出
摘要 与年龄或某些骨骼疾病相关的骨细胞空间排列方向的变化引起了研究者们的广泛关注.本研究的目的是通过建立骨细胞相对于骨内流体流动轴偏转0°、30°、45°、60°和90°的骨单元多孔弹性力学模型,证明骨细胞方向对骨内流体流动的影响.我们假设骨陷窝-小管网络规则排列且均匀分布,且将骨单元定义为由微观尺度水平上的代表性立方周期单元(CPUC)组成.通过计算骨细胞周围骨小管的数量和3D分布来估算骨单元的微观结构参数(渗透率、孔隙率等),并建立骨单元孔隙弹性有限元模型,研究不同边界条件和载荷形式下负载诱导的骨内间质流体流动和骨内营养物质运输.结果表明,在接近正常生理活动的载荷条件下,骨细胞方向对骨单元最大流体压力(p)、最大流体速度(v)和最大流体剪切应力(τ)都有显著的影响.p值和τ值在骨单元壁内呈现不均匀分布,这说明骨细胞方向和骨小管三维分布是预测骨陷窝-小管系统渗透性各向异性程度的重要参数,但骨细胞方向对骨内营养物质运输影响很小.此外,载荷形式和骨陷窝-小管弯曲度对骨单元的液体流动行为的影响大于骨细胞方向对其的影响.这项研究的结果将有助于人们准确量化骨内液体流动行为,并增强对骨的力传导机制的理解. Changes in osteocyte spatial arrangement and orientation that are associated with aging and certain bone diseases have attracted much attention.The purpose of the current study is to demonstrate effects of osteocyte orientation on the deflection of fluid flow in bone by modeling osteocytes rotated by 0°,30°,45°,60°,and 90°relative to the bone fluid flow axis.The lacunocanalicular network was assumed to be regularly arranged and uniformly distributed and the osteon was defined as a representative cubic periodic unit cell(CPUC)at the microscale level.Calculation of canaliculi number and distribution around the osteocyte enabled estimation of osteon microstructural parameters toward the establishment of an osteon poroelastic finite element model to investigate specific loading-induced interstitial fluid flow and nutrient transport parameters in the bone under different boundary conditions and loading types.The results showed that osteocyte orientation under loading conditions approximating normal physiological loads markedly influenced predicted osteon maximum fluid pressure(p),fluid velocity(v),and fluid shear stress(τ)values.Moreover,results showing the nonuniform distribution of p andτvalues within the osteon wall indicated that osteocyte orientation and canaliculi three-dimensional distribution were important parameters for predicting the degree of anisotropy of lacuno-canalicular system permeability,of anisotropy of lacuno-canalicular system permeability,while also demonstrating that osteocyte orientation had little effect on nutrient transport.Furthermore,loading type and lacunocanalicular tortuosity effects on osteon fluid flow were greater than osteocyte orientation-associated effects.The results of this study may help researchers accurately quantify bone fluid flow behavior to enhance understanding of mechanotransduction mechanisms in bone.
作者 于纬伦 刘昊庭 霍旭阳 杨风健 杨晓航 楚智媛 时念秋 武晓刚 陈维毅 Weilun Yu;Haoting Liu;Xuyang Huo;Fengjian Yang;Xiaohang Yang;Zhiyuan Chu;Nianqiu Shi;Xiaogang Wu;Weiyi Chen(College of Biomedical Engineering,Jilin Medical University,Jilin 132013,China;Department of Pharmaceutics,School of Pharmacy,Jilin Medical University,Jilin 132013,China;College of Pharmaceutical Sciences,Yanbian University,Yanbian 133002,China;College of Biomedical Engineering,Taiyuan University of Technology,Taiyuan 030024,China)
出处 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2023年第6期179-197,共19页 力学学报(英文版)
基金 supported by the Department of Science and Technology of Jilin Province(Grant No.YDZJ202201-ZYTS568) the National Natural Science Foundation of China(Grant No.82172593) the Doctoral Program Foundation of Jilin Medical University(Grant No.JYBS2021025LK).
关键词 液体流动 骨细胞 空间排列 网络规则 正常生理活动 骨骼疾病 小管 弯曲度 Osteocyte Poroelastic Fluid shear stress Lacuno-canalicular Finite element model Nutrient transport
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部