期刊文献+

浅谈地铁车站主体结构防水施工技术

On construction technology of waterproof for main body structure of subway station
下载PDF
导出
摘要 在地铁的施工中,车站主体结构是极易出现渗漏水问题的部位,其渗漏水问题严重影响到结构的耐久性及使用功能。从排水设计、建筑材料、现场施工等方面分析漏水原因,在结构设计、材料选择、施工及养护等方面提出相应的解决措施,以期为类似工程施工提供借鉴作用。 In the construction of the metro,the main structure of the station is subject to water leaks,which seriously affects the duration and function of the structure.This article analyses the causes of water leaks from urban topography,building materials and site construction,and proposes corresponding solutions in structural design,material selection,construction and maintenance,etc.it is expected to provide reference for similar engineering construction.
作者 闫实 全阳 罗光财 冯刚 哈吉章 YAN Shi;QUAN Yang;LUO Guangcai;FENG Gang;HA Jizhang(China Construction Fifth Engineering Bureau Co.,Ltd.,Changsha 410000,China;Xiangtan University,Xiangtan 411100,China)
出处 《四川建材》 2023年第11期118-119,122,共3页 Sichuan Building Materials
关键词 地铁车站主体结构 漏水原因 防水措施 main body structure of subway station leaking reasons waterproof measures
  • 相关文献

参考文献12

二级参考文献42

共引文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部