期刊文献+

X射线球面弯晶成像性能分析及实验测试

Performance Analysis and Experimental Test of X-Ray Spherically Curved Crystal Imaging
原文传递
导出
摘要 在惯性约束聚变及实验室天体物理研究中,均需要对等离子体的形态进行清晰的成像,同时具有单色、高分辨、大视场的X射线球面弯晶背光成像是其中一项关键的诊断技术。本文首先对球面弯晶背光成像技术的成像性能进行分析,获得了空间分辨率、成像效率等性能参数随成像系统设计参数变化的关系。在此基础上,利用神光II高功率激光辐照Si靶,激发产生1.865 keV的Heα线,对球面弯晶背光成像系统的性能进行实验验证。实验得到清晰的网格图像和生物样品图像,实验结果与理论计算值相符,成像分辨率达到4.8μm。该工作满足X射线弯晶成像高分辨率的要求,可用于惯性约束聚变等相关实验中激光等离子体的精密诊断。 Objective Due to the insufficient understanding of the complex physical processes during fusion,research on inertial confinement fusion(ICF)has reached a plateau after decades of rapid development.Therefore,the development of diagnostic techniques under extreme transient conditions is crucial to advance the research on ICF.Large amounts of plasma X-rays are generated in the fusion process.Both the continuum and the line spectra of the X-rays contain a large amount of information about the plasma parameters and the fusion process,including the plasma temperature,density,spatial scale,etc.The diagnosis of high-temperature plasma X-rays is extremely important in the diagnosis of ICF.X-ray spherically curved crystal imaging with monochromatic,high resolution,and large field of view is one of the key diagnostic techniques.Spherically curved crystal imaging technology can achieve one-dimensional spectral resolution imaging,twodimensional monochromatic self-illumination imaging,and two-dimensional monochromatic backlight imaging.Compared with self-illumination imaging,spherically curved crystal backlight imaging has lower requirements for backlight radiation power and can achieve higher spatial resolution and narrower spectral resolution.The resolution ability of the spherically curved crystal backlight imaging system is an important indicator of this diagnostic method.However,at present,there are still few studies on the spherically curved crystal backlight imaging system in China,and compared with the international best resolution ability,it also needs to be further improved.Therefore,in this paper,the imaging performance of the spherically curved crystal backlight imaging system was analyzed in detail,and the experimental test was carried out on SG-Ⅱhigh-power laser device.It is hoped that the resolution of the system can be further improved by the reasonable design of experimental parameters so that the spherically curved crystal backlight imaging system can be used for the precision diagnosis of laser plasma in ICF.Methods To explore the imaging performance of the spherically curved crystal backlight imaging system,we focused on both theoretical and experimental aspects.In theory,the influences of system parameters,aberration,small error of the bending crystal radius,and other factors on imaging performance were analyzed.The variation curves of performance parameters with each influencing factor were plotted,which provided theoretical support for the analysis of subsequent experimental results.Based on the theoretical analysis,the specific system parameters were determined.The X-ray source was 360 mm away from the curved crystal,and the imaging object was 230 mm away from the curved crystal;the detector was placed about 3700 mm away from the curved crystal,and the size of the backlight was about 200μm.Then the imaging performance of the imaging system was tested by the SG-Ⅱhigh-power laser device.The Heαline of 1.865 keV excited by laser irradiation of the Si target was selected as the backlight source,with a wavelength of 0.665 nm.The quartz crystal,pressed into a spherically curved crystal with a radius of curvature of 433 mm,was the core imaging element.The Image Plate was chosen as the detector for the backlight imaging and system commissioning phase.The Andor X-ray CCD,with its own higher resolution,was chosen as the detector for the formal imaging phase.In order to check the imaging performance of the imaging system,a Cu grid with 1500 meshes was first imaged,and a grid image with a resolution of approximately 4.8μm was obtained.In order to further validate the imaging performance of the imaging system,cicada wing specimens were imaged,and clear images of cicada wing specimens were obtained using numerical methods.Results and Discussions Firstly,there were inevitable aberrations in the imaging system which could affect the image quality of the imaging system.Spherical aberration,coma,dispersion,and aberrations in spherically curved crystal backlight imaging systems were theoretically analyzed,and appropriate aberration correction methods were given.The effect of the spherical bend radius error on imaging performance was then investigated,and the equations for the relative rate of change of magnification and spatial resolution caused by the bend radius error were derived.The relative rate of change curves was plotted(Fig.5).Secondly,experimentally clear grid images were obtained by using a spherically curved crystal imaging system,and the resolution of the grid images was obtained by edge function fitting down to 4.8μm(Fig.6).In order to obtain more accurate statistical results,the best imaging position in the grid image was calibrated,and the variation of resolution in the meridional and sagittal directions with deviation from the best imaging position was analyzed(Fig.7).Within a range of 200μm from the optimum imaging position,resolutions of down to 4.7μm in the meridional direction and 4.83μm in the sagittal direction could be achieved.Even at the edges,where there was a lot of distortion and noise,it was possible to achieve a resolution of 9.95μm.Finally,in order to validate the imaging performance of the imaging system on biological samples,cicada wing specimens were imaged.However,due to small deviations in the collimation process,the signal-to-noise ratio of the images was relatively low.Data processing of the images using the Retinex algorithm improved the contrast of the images,resulting in clear images of biological specimens(Fig.9),which proved that the imaging system could also be used for the diagnosis of biological specimens.Conclusions We presented a theoretical analysis of the imaging performance of the spherically curved crystal backlight imaging system and discussed the effects of system parameters,aberrations,small errors of the bending crystal radius,and other factors on the imaging performance.A theoretical basis was provided for the subsequent design of experimental parameters and analysis of experimental results.In the experiments,the X-ray spherically curved crystal backlight imaging system was constructed by using a quartz crystal.X-ray CCD was chosen as the detector.The experiments were performed by using SG-Ⅱhigh-power laser device.Clear images were obtained for the metal grid and biological samples respectively.Further analysis of the grid images showed that the high spatial resolution of about 4.8μm could be maintained.Therefore,the spherically curved crystal backlight imaging system is capable of high-resolution imaging over a large field of view and can be used for the precision diagnosis of hightemperature plasma in ICF.In further experiments,we will reduce the effect of noises on an image by adding filters and collimation modules or reducing the size of the backlight to improve the resolution of the spherically curved crystal backlight imaging system.
作者 钟肖彤 刘会亚 董全力 康宁 张杰 Zhong Xiaotong;Liu Huiya;Dong Quanli;Kang Ning;Zhang Jie(Department of Science,Harbin Institute of Technology(Weihai),Weihai 264209,Shandong,China;Department of Physics,Harbin Institute of Technology,Harbin 150001,Heilongjiang,China;National Laboratory on High Power Lasers and Physics,Shanghai Institute of Optics and Fine Mechanics,Chinese Academy of Sciences,Shanghai 201800,China;Collaborative Innovation Center of IFSA,Shanghai Jiao Tong University,Shanghai 200240,China;Beijing National Laboratory of Condensed Matter Physics,Institute of Physics,Chinese Academy of Sciences,Beijing 100190,China)
出处 《光学学报》 EI CAS CSCD 北大核心 2023年第19期305-313,共9页 Acta Optica Sinica
基金 国家自然科学基金(12034020) 山东省自然科学基金重大基础研究项目(ZR2019ZD44) 中国科学院战略性先导科技专项A类(XDA25030300)。
关键词 X射线 球面弯晶 背光成像 空间分辨 X-ray spherically curved crystal backlight imaging spatial resolution
  • 相关文献

参考文献5

二级参考文献35

  • 1常增虎,山冰,刘秀琴,杨鸿儒,朱文华,刘进元,侯继东,龚美霞.微通道板选通X射线皮秒分幅相机[J].光子学报,1995,24(6):501-508. 被引量:15
  • 2李东,刘百玉,刘进元,欧阳娴,白永林,白晓红,王琛,田进寿,黄蕾,李辉.用于高功率激光装置中的电脉冲整形系统[J].光子学报,2005,34(9):1304-1306. 被引量:10
  • 3白晓红,刘进元,白永林,刘百玉,刘秀琴,王琛.高效透明导电膜荧光屏的研究[J].光子学报,2006,35(2):176-179. 被引量:7
  • 4Pikuz S A, Shelkovenko T A, Romanova V M, et al. High-luminosity monochromatic X ray backlighting using an incoherent plasma source to study extremely dense plasmas[J]. Rev Sci Instrum, 1997,68(1) :740-744.
  • 5Aglitskiy Y, Lehecka T, Obenschain S, et al. High-resolution monochromatic X-ray imaging system based on spherically bent crystals[J]. Appl Opt, 1998,37(22): 5253-5261.
  • 6Koch J A, Aglitskiy Y, Brown C, et al. 4.5 and 8 keV emission and absorption X-ray imaging using sphereically bent quartz 203 and 211 crystals[J]. Rev Sci Instrum, 2003,74(3) : 2130-2135.
  • 7Aglitskiy Y, Obenschain S, Yunkin V. Bent Bragg-Fresnel lenses for X-ray imaging diagnostics[J]. Rev Sci Instrum, 2003,74(3):2228- 2231.
  • 8Fujita K, Nishimura H, Nilci I, et al. Monochromatic X-ray imaging with bent crystals for laser fusion research[J]. Rev Sci Instrum, 2001, 72(1): 744-747.
  • 9Sinars D B, Cuneo M E, Bennett G R, et al. Monochromatic X-ray backlighting of wire-array Z-pinch plasmas using spherically bent quartz crystals[J]. Rev Sci Instrum, 2003,74(3) : 2202-2205.
  • 10Sinars D B, Bennett G R, Wenger D F, et al. Monochromatic X-ray imaging experiments on the Sandia National Laboratories Z facility[J]. Rev Sci Instrum, 2004,75(10) :3672-3677.

共引文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部