摘要
烟台台SS-Y伸缩仪EW分量在2023-02-06土耳其7.8级双震前2 d开始出现急速上升趋势变化,至6日凌晨开始下降,变化幅度达到9.58×10^(-8),震后维持快速上升趋势。对烟台台伸缩仪稳定性指标进行判定,认为仪器稳定;经现场核实,未发现环境干扰。最后对烟台台伸缩仪固体潮畸变特征进行分析,并基于畸变与远震前兆的关系进行初步探讨。
The EW component of SS-Y tensometer at Yantai station began to show a rapid upward trend 2 days before the 2023-02-06 Türkiye M7.8 double earthquakes,and began to turn downward in the early morning of 2023-02-06,with a range of 9.58×10^(-8),and maintained a rapid upward trend after the earthquakes.The stability index of Yantai tensometer is judged and it is considered that the instrument is stable.After on-site verification,no environmental interference was found.Finally,the characteristics of the earth tide distortion are analyzed,and the relationship between the distortion and the distant earthquake precursor is discussed.
作者
郝军丽
朱成林
张正帅
赵洋
王合乾
HAO Junli;ZHU Chenglin;ZHANG Zhengshuai;ZHAO Yang;WANG Heqian(Shandong Earthquake Agency,20 East-Wenhua Road,Ji’nan 250014,China;Yantai Earthquake Monitoring Center Station,17 Nanshangou,Yantai 264000,China)
出处
《大地测量与地球动力学》
CSCD
北大核心
2023年第12期1313-1316,1320,共5页
Journal of Geodesy and Geodynamics
基金
中国地震局地震科技星火计划(XH21018)。
关键词
烟台地震台
伸缩仪
EW分量
固体潮畸变
土耳其地震
Yantai station
tensometer
EW component
earth tide distortion
earthquakes in Türkiye