摘要
建筑结构设计是否安全、经济、合理,与选定的结构方案密切相关。文章以西安市红会医院门诊楼单体局部为例,结合医疗建筑的特点,给出了高烈度地区多层门诊楼常采用的框架结构与框架—剪力墙结构的体系对比,分析两者的抗震性能、材料用量并提出应注意的常见问题,为高烈度地震区多层医疗建筑的设计提供思路与建议。
Whether the structural design of the building is safe,economical and reasonable is closely related to the selected structural scheme.Taking part of the outpatient building of Xi'an Honghui Hospital as an example,combined with the characteristics of medical buildings,it compares the commonly used frame structure and frame-shear wall structure in the multi-storey outpatient clinic in the high intensity earthquake areas;analyzes the seismic performance and material consumption of the two,and puts forward common problems that should be paid attention to,so as to provide ideas and suggestions for the design of multi-storey medical buildings in high-intensity earthquake areas.
作者
丁亚静
刘建飞
李利民
赵泽锋
李昕
DING Yajing;LIU Jianfei;LI Limin;ZHAO Zefeng;LI Xin
出处
《中国医院建筑与装备》
2023年第9期44-48,共5页
Chinese Hospital Architecture & Equipment
关键词
医疗建筑
高烈度地震区
结构体系
框架结构
Medical buildings
High-intensity earthquake areas
Structural system
Frame structure