期刊文献+

天然气管道压缩机组DCP/UPS电源的安全环保节能改造 被引量:1

SAFETY,ENVIRONMENTAL PROTECTION AND ENERGY CONSERVATION REVAMP OF DCP/UPS POWER SUPPLY FOR COMPRESSOR UNIT IN NATURAL GAS PIPELINE
下载PDF
导出
摘要 我国天然气管道初期工程中大量采用国外先进压缩机技术,由于其采用国外标准和根据国外供电条件设计,在我国的实际应用中产生很多问题,供电问题是其中的一种。文章基于目前天然气压气站供电状况存在的问题,提出了采用国产电源替代的节能改造方案。改造前的DCP/UPS电源采用相控模式,效率只有70%左右,改造后效率可提高至92%。DCP/UPS电源改造已在西气东输、西部管道及陕京线成功改造了50多套。实践证明:用国产DCP/UPS电源替代,不仅设计合理、运行可靠,维护方便,而且备件充足、成本低。 A large number of foreign advanced compressor technologies were adopted in the initial projects of China’s natural gas pipeline.And because they were designed by adopting foreign standards and according to foreign power supply conditions,many problems arose from their practical application in China,of which the problem of power supply is one of them.Based on the problems existing in the current power supply of natural gas compressor stations,this paper proposed an energy conservation revamp program using substitution of domestic power supply.Before the revamp,the DCP/UPS power supply was in phase-controlled mode with an efficiency of only about 70%,and the efficiency can be increased to 92% after the revamp.DCP/UPS power supply revamp has been successfully carried out in more than 50 sets in West-East Gas Pipeline,Western Pipeline and Shaanxi-Beijing Pipeline.Practice has proved that with the domestic DCP/UPS power supply replacement,the design is reasonable;the operation is reliable and the maintenance is convenient.In addition,the spare parts are sufficient and the cost is low.
作者 刘风明 吕开钧 范文涛 郑会 李江宁 隋学礼 王岩 杨新平 Liu Fengming;Lyu Kaijun;Fan Wentao;Zheng Hui;Li Jiangning;Sui Xueli;Wang Yan;Yang Xinping(PipeChina West Pipeline Co.,Ltd.,Urumqi,Xinjiang,830000;West-East Gas Transmission Branch of National Pipe Network Group United Pipeline Co.,Ltd.,Shanghai,200122;South-East Asia Gas Pipeline Company Limited,Beijing,100000;PipeChina Beijing Pipeline Co.,Ltd.,Beijing,100000;Qingdao Gomatech Development Co.,Ltd.,Qingdao,Shandong,266101)
出处 《石油化工安全环保技术》 CAS 2023年第4期30-34,I0002,共6页 Petrochemical Safety and Environmental Protection Technology
关键词 DCP/UPS 逆变模块 直流模块 监控单元 节能 DCP/UPS inverter module DC module monitoring unit energy conservation
  • 相关文献

参考文献2

二级参考文献36

  • 1刘国起.用变频器自动重起功能消除电网瞬时低压或瞬时停电[J].电工技术,2006(1):76-76. 被引量:2
  • 2孔维涛,张庆范,李瑞来,何洪臣.电网瞬时停电保持变频器母线电压的新方法[J].电工技术学报,2006,21(6):54-58. 被引量:5
  • 3张海涛,赵争鸣,袁立强,钱珏,鲁挺.一种新的应用于高压大容量变频器的失电跨越控制策略[J].电工电能新技术,2006,25(3):68-72. 被引量:6
  • 4韩安荣.通用变频器及其应用[M].北京:机械工业出版社,2002..
  • 5KIM K, LEE J M, LEE I B. A novel multivariate regres- sion approach based on kernel partial least squares with orthogonal signal correction [ J]. Chemometrics and Intel- ligent Laboratory Systems, 2005, 79(1-2) : 22-30.
  • 6JIA R D, MAO Z Z, CHANG Y Q, et al. Kernel partial robust M-regression as a flexible robust nonlinear model- ing technique[ J]. Chemometrics and Intelligent Labora- tory Systems, 2010, 100(2) : 91-98.
  • 7JIA M X, CHU F, WANG F L, et al. On-line batch process monitoring using batch dynamic kernel principal component analysis [ J]. Chemometrics and Intelligent Laboratory Systems, 2010, 101(2) : 110-122.
  • 8WOLD S, SJOSTROM M, ERIKSSON L. PLS-regression a basic tool of chemometrics [ J]. Chemometrics and In- telligent Laboratory System, 2001, 58 (2) : 109-130.
  • 9JIANG W, KHAN J, DOUGAL R A. Dynamic centrifu- gal compressor model for system simulation[ J ]. Journal of Power Sources, 2006, 158 : 1333-1343.
  • 10COHEN H, ROGERS G F C, SARAVANAMUTFO0 H I H. Gas turbine theory [ M]. 4th ed. Essex, U. K. : Longman, 1996.

共引文献47

同被引文献9

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部