期刊文献+

土壤三普指定方法测砷汞与行业标准比对探讨

Comparison of Arsenic Mercury Measurement with Industrial Standard by Three-general Methods
下载PDF
导出
摘要 时隔40年,我国终于在2022年迎来了全国第三次土壤普查,这40年来,我国经历了快越式发展,城乡加速融合,但是由于这40年来的不合理开发,环境也受到了巨大的影响,为全面掌握土壤资源状况,国家将全面展开第三次土壤普查。本次将根据土壤三普测定砷和汞指定用国家标准《土壤质量总汞、总砷、总铅的测定原子荧光法》(GB/T 22105-2008)和行业标准《土壤和沉积物砷、汞、硒、锑、铋的测定微波消解/原子荧光法》(HJ 680-2013)进行一次方法比较,寻求效益更好的科学技术,以便于之后使用。 After 40 years,China finally ushered in the third national soil survey in 2022.Over the past 40 years,China has experienced rapid development and accelerated urban-rural integration.However,due to the unreasonable development in the past 40 years,the environment has also been greatly affected.In order to fully grasp the status of soil resources,the state will carry out the third soil survey in an all-round way.This time,a method comparison will be made according to the national standard for the determination of total mercury,total arsenic and total lead in soil quality atomic fluorescence method(GB/T 22105-2008)and the industrial standard microwave digestion/atomic fluorescence method for the determination of arsenic,mercury,selenium,antimony and bismuth in soil and sediments(HJ 680-2013),so as to seek more effective science and technology for later use.
作者 杨超杰 刘文水 YANG Chao-jie;LIU Wen-shui(Guangdong Vocational and Technical College of Light Industry,Guangdong Foshan 528200;Guangdong Yuanchuang Testing Technology Co.,Ltd.,Guangdong Guangzhou 511300,China)
出处 《广州化工》 CAS 2023年第14期127-129,共3页 GuangZhou Chemical Industry
关键词 原子荧光光度计 微波消解仪 可控温电热板 相对标准偏差 加标回收率 atomic fluorescence spectrophotometer microwave digestion instrument controllable temperature electric heating plate relative standard deviation standard recovery
  • 相关文献

参考文献8

二级参考文献40

共引文献52

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部