摘要 由于工业和城市发展的快速增长,电力需求持续上升,我国的电力供应不断增加。本文介绍了电力设备高压绝缘试验的主要类型,对当前存在的触电和人员中毒问题进行了剖析,并深入研究了高压电力设备绝缘试验的方法和主要安全措施,希望能为稳定电网运行状态提供一些参考。 Due to the rapid growth of industrial and urban development,the demand for electric power continues to rise,and the power supply continuously increases in China.This paper introduces the main types of high-voltage insulation test of electric power equipment,analyzes the current problems of electric shock and human poisoning,and deeply studies the insulation test methods and main safety measures of high-voltage electric power equipment,hoping to provide the reference for stabilizing power grid operation.
作者 宋桃 Song Tao(Guangdong Weiheng Power Transmission and Transformation Engineering Co.,Ltd.,Foshan 528200,Guangdong Province,China)
出处 《科学与信息化》 2023年第23期114-116,共3页 Technology and Information
关键词 高压电力设备 绝缘试验 安全措施 high-voltage electric power equipment insulation test safety measure