摘要
介绍了基于美国标准ANSI ANS-56.8《Containment System Leakage Testing Requirements》的要求和计算方法建立的安全壳整体密封性试验验证试验装置的结构和布置。对目前国内验证试验实施方式进行了分析,提出了实施方式的缺点,并提出了针对性的改进建议。
Apparatus structure and arrangement in the testing verification of containment integrated leakage rate based on requirement and calculation method in the American standard ANSI ANS-56.8 Containment System Leakage Testing Requirements are described.By analyzing the processing method of verification test currently applied in China,the disadvantages are revealed and suggestions of improvement countermeasures are proposed.
作者
常楠
尤坤坤
刘硕
屠晨浩
肖博懿
CHANG Nan;YOU Kunkun;LIU Shuo;TU Chenhao;XIAO Boyi(State Nuclear Power Plant Service Company,Shanghai 200233,China)
出处
《电工技术》
2023年第19期130-131,135,共3页
Electric Engineering
关键词
安全壳
整体密封性试验
泄漏率
验证试验
containment
integrated leakage rate test
leakage rate
verification test