摘要
2021年9月至2022年2月期间菏泽地电场观测数据出现异常变化,台站工作人员通过对观测系统、外装置系统、电极、观测室用电线路巡检、测试和主备机对比观测等方式,查找干扰源,在排除地球物理场异常变化后,认为此次数据异常变化是由电极老化和电极引线与外线路接线处接触不良造成的。
From September 2021 to February 2022,abnormal changes were observed in the geoelectric field observation data in Heze.To identify the cause of the anomalies,station personnel conducted anomaly recognition and interference elimination work.Through inspections,tests,and comparisons between the main and backup systems of the observation system,external device system,electrodes,and electrical circuits in the observation room,interference sources were identified.After eliminating abnormal changes in the geophysical field,it was determined that the abnormal data variation was caused by electrode aging and poor contact between the electrode lead and external circuits.
作者
申茂正
周铭辉
张军
陈亚红
张继红
冯梁乐
SHEN Maozheng;ZHOU Minghui;ZHANG Jun;CHEN Yahong;ZHANG Jihong;FENG Liangle(Heze Seismic Monitoring Center Station,Shandong Earthquake Agency,Heze,Shandong 274000,China;Shandong Earthquake Agency,Jinan,Shandong 250014,China)
出处
《山西地震》
2023年第4期52-55,共4页
Earthquake Research in Shanxi
关键词
地电场
干扰
异常识别
接触不良
geoelectric field
interference
anomaly recognition
poor contact