摘要 采用处理能力为1.5 m^(3)/d的真空紫外耦合多级过滤系统对市政供水管网末端出水进行处理,连续监测该系统对管网末端出水中有机微污染物(莠去津)、可同化有机碳(AOC)、微生物、余氯、消毒副产物(三氯甲烷)和溶解性有机物的去除效果。结果表明,该系统在运行期间可以将水中的莠去津全部去除,出水AOC保持在70μg/L以下,菌落总数保持在10 CFU/mL以下。此外该系统对饮用水中溶解性有机物也有很好的去除效果。该系统可以有效地提升管网出水水质,为人民群众的饮用水健康安全提供保障。 A vacuum ultraviolet coupled with multistage filtration system with a treatment capacity of 1.5 m^(3)/d was employed to treat the effluent from the end of a municipal water supply network.The performances of the system for the removal of organic micropollutants(atrazine),assimilable organic carbon(AOC),microorganisms,residual chlorine,disinfection byproducts(trichloromethane)and dissolved organic matter were continuously monitored.The system removed all atrazine in water during the operation.The effluent AOC was always less than 70μg/L,and the total number of microbial colonies was below 10 CFU/mL.In addition,the system also had a good removal efficiency on dissolved organic matter in drinking water.The system effectively improved the water quality of the water supply network and ensured the health and safety of drinking water for the people.
作者 罗从伟 王金晓 王士顺 杨曦凯 翟学东 谭凤训 武道吉 成小翔 陈飞勇 LUO Cong‑wei;WANG Jin‑xiao;WANG Shi‑shun;YANG Xi‑kai;ZHAI Xue‑dong;TAN Feng‑xun;WU Dao‑ji;CHENG Xiao‑xiang;CHEN Fei‑yong(School of Municipal and Environmental Engineering,Shandong Jianzhu University,Jinan 250101,China;Resources and Environment Innovation Institute,Shandong Jianzhu University,Jinan 250101,China;Jinan Municipal Engineering Design&Research Institute<Group>Co.Ltd.,Jinan 250003,China;Ordos Anxintai Environment Protection Technology Co.Ltd.,Ordos 017000,China)
出处 《中国给水排水》 CAS CSCD 北大核心 2023年第23期53-58,共6页 China Water & Wastewater
基金 山东省引进顶尖人才“一事一议”项目(0031504) 国家自然科学基金资助项目(52270200) 济南市市校融合发展战略工程项目(JNSX2021048)。
关键词 真空紫外 多级过滤 自来水 深度处理 vacuum ultraviolet multistage filtration tap water advanced treatment
  • 相关文献

参考文献6

二级参考文献76

  • 1贾凤莲,黎泽华,王同春.超滤-反渗透技术在慈东自来水厂的应用[J].水工业市场,2009(12):71-73. 被引量:1
  • 2谢曙光,张湛军,刘妤笑,施东文,王占生.臭氧生物炭深度处理低温黄河水研究[J].中国给水排水,2004,20(7):21-24. 被引量:13
  • 3徐兵,王建良,施力.湖州基山村超滤膜水厂工程介绍[J].中国给水排水,2006,22(14):49-51. 被引量:5
  • 4王超,胡洪营,王丽莎,田杰,藤江幸一.典型含氮有机物的氯消毒副产物生成潜能研究[J].中国给水排水,2006,22(15):9-12. 被引量:34
  • 5奕永庆,黄姚松.超滤膜饮用水设备在余姚山区农村应用效果分析[J].中国水利,2007(10):124-125. 被引量:5
  • 6Park M N, Jang H N, Lee D S, et al. Coagulation pretreatment for drinking water treatment by membrane process of river water [ A ]. 5^th IWA Conference on Membranes for Water and Wastewater Treatment [ C ]. Beijing : IWA - MTC 2009 Organising Committee ,2009.
  • 7Huek P M, Peldszus S, Hallo C ,et al. Pilot scale evaluation of biofiltration as an innovative pretreatment for UF membranes for drinking water treatment [ A]. 5^th IWA Conference on Membranes for Water and Wastewater Treatment[ C ]. Beijing: IWA - MTC 2009 Organising Committee, 2009.
  • 8Gmtinder A,Vescoli D. Membranes in multi-barrier systems for the treatment of surface water [ A ]. 5^th IWA Conference on Membranes for Water and Wastewater Treatment[ C ]. Beijing: IWA - MTC 2009 Organising Committee, 2009.
  • 9Soussan L, Guigui C,Alfenore S,et al. Use of new tracers for the assessment of the inline retention of viruses by membrane systems [ A]. 5^th IWA Conference on Membranes for Water and Wastewater Treatment [ C ]. Beijing : IWA - MTC 2009 Organising Committee,2009.
  • 10Shirasaki N, Matsushita T, Matsui Y,et al. Evaluation of norovirus removal performance in a coagulation-microfiltration process by using recombinant norovirus VLPs [ A]. 5^th IWA Conference on Membranes for Water and Wastewater Treatment [ C ]. Beijing: IWA - MTC 2009 Organising Committee ,2009.

共引文献215

同被引文献6

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部