摘要
对10个环板加劲管板节点进行试验研究和数值分析,研究了环形加劲管板节点在径向荷载作用下的受力性能和失效模式,提出了环板加劲管板节点的失效准则。结果表明:在径向拉力作用下,节点板与加劲环板连接处最终发生断裂破坏,与之相差90°夹角位置处,加劲环板发生局部屈曲;在径向压力作用下,加劲环板发生压屈失效;当节点的变形与主管直径D的比值不大于0.15%时,节点处于弹性;当节点变形与主管直径的比值大于0.15%且小于2.0%时,节点的刚度迅速降低;当节点变形与主管直径比值大于2.0%时,节点已处于塑性且无法继续承载。基于此,提出采用0.02 D极限变形准则来确定节点的极限承载力。
Experimental and numerical investigation on ten ring-stiffened tube-gusset plate joints(RS-TGP joints)has been carried out.The mechanical properties and failure mode of RS-TGP joints under radial tension/compressive were studied.The failure criteria of RS-TGP joints were proposed.The failure mode of the RS-TGP joints under tension performed as tensile broken at the intersection of the gusset plate and ring stiffener while buckling of the ring stiffener at the location perpendicular to the loading direction.The failure mode of the RS-TGP joints under compressive was bulking of the ring stiffener.It was found that the RS-TGP joint was elastic when the ratio of joint deformation to chord diameter was less than or equal to 0.15%.However,the stiffness of the joint decreased rapidly as the ratio of the joint deformation to the chord diameter was greater than 0.15%and less than 2.0%.When the ratio of joint deformation to chord diameter was larger than 2.0%,the RS-TGP joint was in a plastic state and unable to carry the load.Thus,the ultimate bearing capality of the joint was determined by the failure criterion of the 2%D limit.
作者
袁俊
屈讼昭
王虎长
卫思彤
孙清
YUAN Jun;QU Songzhao;WANG Huchang;WEI Sitong;SUN Qing(Northwest Electric Power Design Institute Co.,Ltd.,of China Power Engineering Consulting Group,Xi’an 710075,China;School of Civil and Transportation Engineering,Henan University of Urban Construction,Pingdingshan Henan 467036,China;School of Human Settlements and Civil Engineering,Xi’an Jiaotong University,Xi’an 710049,China)
出处
《工业建筑》
北大核心
2023年第11期156-160,187,共6页
Industrial Construction
基金
中国能源建设集团规划设计有限公司科技项目(GSKJ2-T07-2019)
国家自然科学基金资助项目(51978570)。
关键词
管板节点
环板
受力性能
失效准则
极限承载力
tube-gusset plate joint
ring stiffener
mechanical property
failure criterion
ultimate bearing capacity strength