针对500 kA新型节能电解槽非正常期的特点,研究工艺参数控制范围,采取操作与维护管理措施,启动后的电解槽槽平均电压≤3.88 V,电流效率≥93%,具有较好的节能效果,为同类槽型非正常期管理控制提供实践经验。
For the features of 500 kA new energy-saving electrolytic cell in abnormal period,the process parameters of control range was studied,so the operation and maintenance management measures were taken,then the average voltage of the restart electrolytic cell≤3.88 V,the current efficiency≥93%,it can get better energy-saving results,and it can provide practical experience to the same cells in abnormal period.
作者
张伟
张鹏程
李官福
王辉
赵志强
ZHANG Wei;ZHANG Peng-cheng;LI Guan-fu;WANG Hui;ZHAO Zhi-qiang(Yunnan Wenshan Aluminum Co.,Ltd.,Wenshan,Yunnan 663000,China)
出处
《云南冶金》
2023年第6期197-203,共7页
Yunnan Metallurgy
关键词
节能电解槽
非正常期
电解质温度
电解质水平
铝水平
槽电压
energy-saving electrolytic cell
abnormal period
electrolyte temperature
electrolyte level
aluminum level