期刊文献+

煤矿综采面远距离供电技术方案

Technical Scheme for Long-Distance Power Supply in Fully Mechanized Coal Mining Face
下载PDF
导出
摘要 为解决矿井1601综采工作面在远距离供电过程中的压降损失、无功损耗及谐波产生等问题,本文首先分析了高压防爆SVG集中补偿方案、电路终端电压调节控制方案、低压防爆SVG终端补偿方案、设备变频软启动方案的技术原理和技术,进而基于工作面具体条件设计了高低压无功补偿、终端电压调节及设备软启动变频改造的综合治理方案。该方案较好地解决了远距离供电带来的各种弊端,年节约电费可达85.5万元,技术经济效益显著。 To address the issues of voltage drop loss,reactive power loss,and harmonic generation during long-distance power supply in the 1601 fully mechanized mining face of the mine,this paper first analyzes the technical principles and technologies of high-voltage explosion-proof SVG centralized compensation scheme,circuit terminal voltage regulation control scheme,low-voltage explosion-proof SVG terminal compensation scheme,and equipment frequency conversion soft start scheme.Based on the specific conditions of the working face,high-voltage and low-voltage reactive power compensation are designed comprehensive governance plan for terminal voltage regulation and equipment soft start frequency conversion transformation.This solution effectively solves various drawbacks caused by long-distance power supply,saving annual electricity costs up to 855 000 yuan,and achieving significant technical and economic benefits.
作者 杨栋栋 YANG Dongdong(Shanxi Fenxi Yixing Coal Industry Co.,Ltd.,Yixing,Shanxi 032300,China)
出处 《自动化应用》 2023年第24期73-74,77,共3页 Automation Application
关键词 远距离供电 无功补偿 谐波抑制 供电保护 long-distance power supply reactive power compensation harmonic suppression power supply protection
  • 相关文献

参考文献7

二级参考文献56

共引文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部