摘要
采用离子色谱仪检测工业甲醇中微量氯离子的方法,需首先对甲醇样品进行浓缩处理,使用阴离子柱为分析柱,热导检测器,分析检测的RSD为5.9%,回收率为92.0%~100%,检测限为0.02 mg/L,可以满足工业甲醇中微量甲醇氯离子含量的检测需要。
This article uses an ion chromatograph to detect trace chloride ions in industrial methanol.Firstly,the methanol sample is concentrated and treated using an anion column as the analysis column and a thermal conductivity detector.The RSD for analysis and detection is 5.9%,the recovery rate is 92.0%~100%,and the detection limit is 0.02 mg/L.This can meet the needs of detecting trace chloride ions in industrial methanol.
作者
王业超
章小龙
胡威盛
高帆
焦彬彬
Wang Yechao;Zhang Xiaoong;Hu Weisheng;Gao Fan;Jiao Binbin(CNOOC Fudao Co.,Ltd.,Dongfang 572600)
出处
《石化技术》
CAS
2024年第1期9-11,共3页
Petrochemical Industry Technology
关键词
甲醇
离子色谱
氯离子
methanol
Ion chromatography
Chloride ion