摘要 建立标准加入-电感耦合等离子体原子发射光谱法(ICP-AES)测定氯化钠中Cu、Ni元素的分析方法。确定氯化钠中Cu、Ni的分析谱线为Cu 327.395 nm和Ni 230.299 nm。采用标准加入法消除基体干扰,使用耐高盐的OneNeb雾化器提高信号强度,优选高频发生器功率为1.3 kW,雾化气压力为180 kPa。结果表明:Cu、Ni元素的工作曲线呈线性关系,线性相关系数在0.999以上;Cu元素的检出限为0.000 011%,Ni元素的检出限为0.000 031%;测定结果的相对标准偏差(RSD,n=6)在5%以内,样品的加标回收率为96.0%~102.0%。 A standard addition inductively coupled plasma atomic emission spectrometry(ICP-AES)method has been established to determine copper and nickel in sodium chloride.The analytical spectral lines of copper and nickel in sodium chloride was Cu 327.395 nm and Ni 230.299 nm.The interference of sodium chloride matrix was eliminated by standard addition method,and the highly salt-resistant OneNeb nebulizer was used to increase the signal intensity.The preferred power of the high-frequency(RF)generator was 1.3 kW and the nebulizer gas pressure was 180 kPa.The results show that the calibration curves of copper and nickel are linear,and the linear correlation coefficient is above 0.999.The detection limit of copper is 0.000011%,and that of nickel is 0.000031%.The relative standard deviation(RSD,n=6)of the results is within 5%.The added standard recovery of the samples is in the range of 96.0%~102.0%.
作者 宋体杰 严鹏飞 王珏 赵政鑫 刘喜山 闫广利 SONG Ti-jie;YAN Peng-fei;WANG Jue;ZHAO Zheng-xin;LIU Xi-shan;YAN Guang-li(Shenyang Aircraft Corporation,Shenyang 110850,China;Beijing Institute of Aeronautical Materials,Beijing 100095,China)
出处 《失效分析与预防》 2023年第6期369-373,共5页 Failure Analysis and Prevention
关键词 标准加入法 氯化钠 ICP-AES CU NI standard addition method sodium chloride ICP-AES copper nickel
  • 相关文献

参考文献9

二级参考文献61

共引文献43

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部