摘要
该研究建立了一种采用超高效液相色谱-串联质谱(UPLC-MS/MS)同时测定白酒中21种氨基酸含量的检测方法。白酒样品经过12000 r/min离心5 min后,将上清液直接用于色谱分析,外标法定量。结果表明,在10~1000 ng/mL质量浓度范围内,氨基酸含量线性关系良好,相关系数(R2)均>0.995,检出限和定量限分别为0.1~5.0 ng/m L和0.2~20 ng/mL,其保留时间相对标准偏差(RSD)<0.29%,峰面积RSD为1.54%~10.33%,加标回收率为80%~130%。该方法准确可靠,重复性好,可以用于白酒中21种氨基酸的含量的测定。
A method was developed for the simultaneous determination of 21 amino acids in Baijiu using ultra performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).After 12000 r/min centrifugation of Baijiu samples for 5 min,the supernatant was filtered through a membrane for instrumental analysis and quantified by external standard method.The results showed that the standard curve was linear over the mass concentration range of 10-1000 ng/ml with the correlation coefficient(R2)greater than 0.995,the limits of detection were 0.1-5.0 ng/ml and the limits of quantification were 0.2-20 ng/ml,the relative standard deviation(RSD)of the retention time was less than 0.29%,the RSD of the peak area repeatability was in the range of 1.54%-10.33%,and the recovery rate of the target substance was 80%-130%.The method was accurate,reliable and reproducible,and could be used for the determination of 21 amino acids in Baijiu.
作者
张季
杨沙
罗玉航
侯睿
马新雨
朱小兰
ZHANG Ji;YANG Sha;LUO Yuhang;HOU Rui;MA Xinyu;ZHU Xiaolan(Product Quality Inspection and Testing Institute in Zunyi,Zunyi 563099,China;Sichuan Institute of Modern Agricultural Industry,China Agricultural University,Chengdu 611430,China;Agilent Technology(China)Co.,Ltd.,Chengdu Branch,Chengdu 610213,China)
出处
《中国酿造》
CAS
北大核心
2024年第1期250-254,共5页
China Brewing
基金
贵州省科技计划项目(黔科合支撑[2023]一般386)
贵州省科技计划项目(黔科合支撑[2023]一般364)
国家市场监督管理总局科技计划项目(2022MK117)。
关键词
白酒
氨基酸
超高效液相色谱-串联质谱法
Baijiu
amino acid
ultra performance liquid chromatography-mass spectrometry