摘要
基于近场探针的太赫兹扫描成像系统能够突破衍射极限探究物质隐藏的细节,但是传统基于微纳加工工艺的近场探针存在工艺复杂、传输损耗较大的缺点。提出了一种基于空心圆波导的渐变开口圆锥形近场探针设计方法,所设计的探针能够通过圆波导实现低损耗传输,同时利用渐变开口圆锥形针尖实现亚波长聚焦。为了验证方法的可行性,采用3D打印技术对所设计的探针进行加工,然后基于高精度三维扫描平台搭建了一套0.1 THz近场扫描成像系统。实验结果表明该探针能够实现亚波长超分辨聚焦,实验结果与仿真结果一致。
Objective Terahertz imaging technology has broad application prospects in several fields,such as biological detection,medical treatment,data communication,and non-destructive security.However,the long wavelength of terahertz wave,limited by diffraction limitations,only allows the resolution of traditional terahertz imaging technology to be of the wavelength order,which cannot accurately image material details such as biological cell tissues and chip internal circuits.Therefore,the development of terahertz super-resolution imaging technology is particularly important.However,the probes prepared based on traditional micro/nano processing technology present drawbacks such as complex processing and high transmission losses.Based on this,this study proposes a design method for a tapered opening near-field probe based on a hollow circular waveguide.This conical probe can surpass the cutoff wavelength limit to achieve sub-wavelength focusing.In addition,the designed probe is processed using 3D printing technology.Subsequently,a 0.1 THz near-field scanning imaging system is built based on a high-precision 3D scanning platform,and the imaging effect of the processed probe is experimentally tested.The experimental results show that the probe can achieve sub-wavelength superresolution focusing and has high power transmittance,which verifies the feasibility of 3D-printed terahertz near-field probes.Methods First,the structure and size parameters of the tapered probe with a gradient opening are designed.The probe structure is simulated and optimized using CST Studio2019 software.The power density distribution map is examined(Fig.2).To accurately study the focusing effect of the tapered probe with gradient opening on terahertz waves,we numerically characterize the focused terahertz spot:plotting a linear power density distribution curve in the x-direction at the exit port of the probe tip,and considering the x-width at 2/2 of the peak value as the focusing width of the terahertz spot(Fig.3).After optimizing the optimal structural parameters of the probe through simulation,a digital 3D model diagram of the probe is exported.After slicing it in the software,the slicing file is input to a 3D printer for printing.After printing,the surface of the printed product is coated with metal.After the sample production is completed,we build a two-dimensional near-field scanning imaging system to experimentally verify the imaging ability of the prepared probe sample(Fig.6)and evaluate its imaging resolution.Results and Discussions The simulation results of the probe reveal that the designed probe structure bypasses the influence of the cut-off wavelength.The incident terahertz frequency is 0.1 THz,and terahertz focusing can be achieved when the probe tip radius is 0.2 mm.The x-direction focusing width is 0.779 mm,and the y-direction focusing width is 0.4 mm,according to the physical aperture size.In theory,the conical probe structure can achieve a close resolution of 1/4 wavelength,which is super-resolution imaging.Simultaneously,we simulate the focusing spot size of probes with the same size at 0.1 THz and 0.2 THz(Fig.6).The linear power density of the focusing spot at 0.2 THz is roughly 6 times that of the focusing spot at 0.1 THz;the diameter of the focusing spot at 0.1 THz is approximately 0.779 mm;and the one at 0.2 THz is approximately 0.706 mm,with a difference of approximately 0.073 mm.The higher the frequency,the smaller the diameter of the focusing spot,and the higher the resolution.To demonstrate that this probe structure can achieve higher precision terahertz focusing,a proportional reduction is made on the basis of the original design model,and the cone tip aperture of the probe is set to 1μm.This can also form a focused spot at the exit port of the probe.To ensure the printing quality of the near-field probe,we expand the tip radius of the probe to 0.4 mm,and the focusing width of the terahertz spot in the x direction is 1.186 mm,with an power transmittance of 3.16%.In experiments,the imaging resolution of the probe with a tip radius of 0.4 mm is 1.5 mm,and the imaging resolution reaches 1/2 wavelength.The experimental results are consistent with the simulation results.Conclusions This study proposes a design method for a tapered opening near-field probe based on a hollow circular waveguide.Through simulation analysis,this probe inherits the advantages of a high signal-to-noise ratio,a wide band,and no cut-off frequency of gap probes and can achieve sub-wavelength super-resolution focusing.Theoretically,it can achieve micron-level high-resolution imaging.To verify the feasibility of this method,we prepare a terahertz near-field probe structure with a tip radius of 0.4 mm based on 3D printing technology and built a terahertz near-field scanning imaging system for experiments.The experimental results demonstrate that the probe can achieve sub-wavelength super-resolution focusing,achieving an imaging resolution of 1.5 mm at 0.1 THz,reaching 1/2 wavelength,and achieving terahertz super-resolution imaging.The experimental results are consistent with the simulation results,proving the feasibility of a tapered near-field probe based on a hollow circular waveguide.
作者
杨彤
李鑫煜
王正心
龚诚
Yang Tong;Li Xinyu;Wang Zhengxin;Gong Cheng(Tianjin key Laboratory of Micro-scale Optical Information Science and Technology,Institute of Modern Optics,College of Electronic Information and Optical Engineering,Nankai University,Tianjin 300350,China)
出处
《中国激光》
EI
CAS
CSCD
北大核心
2023年第23期246-252,共7页
Chinese Journal of Lasers
基金
国家自然科学基金(61505087)。
关键词
光学设计
3D打印
近场探针
太赫兹
超分辨
optical design
3D printing
near-field probe
terahertz
super-resolution