期刊文献+

用于静态/动态复合信号的改进对称解调技术

Corrected Symmetrical Demodulation Method for Static/Dynamic Composite Signals
原文传递
导出
摘要 提出一种可测量外腔式Fabry-Perot传感器所加载的静态/动态复合信号的腔长自补偿改进对称解调技术。在对称解调技术的基础上,通过其输出信号的直流量判断传感器腔长的变化,从而划分腔长稳定段与突变段,分段并重新进行信号解调,以保证动态分量的解调精度;同时利用腔长变化前后计算出的干涉信号相位差对腔长的变化量进行补偿,以提高静态分量的测量精度。实验证明该解调技术能够实现对静态/动态复合信号的测量。实验中实现了幅度超过100μm复合信号的解调,大幅度腔长变化量的测量误差约为2%。该解调技术能够解调不同腔长传感器上加载的包含高频分量的静态/动态复合信号。 Objective Extrinsic Fabry-Perot interferometers(EFPIs)are widely used in fiber optic sensors.In many applications,the measurand is a mixture of static and dynamic signals.However,laser interference demodulation algorithms used for dynamic signal measurement are significantly different from white light interference demodulation algorithms used for static signal measurement.Laser interference demodulation algorithms require laser wavelengths to remain stable,while white light interference demodulation algorithms require wavelength scanning to obtain the spectrum of the sensor to achieve measurement.Therefore,these measurement techniques can only measure different dynamic signals or different static signals and cannot achieve measurement of static/dynamic composite signals.For EFPI sensors,it is expected to achieve the measurement of static/dynamic composite signals through high-speed white light interferometry demodulation technologies.However,these demodulation technologies are still unable to meet the measurement requirements of high-frequency signals due to limitations in scanning speed.Some high-speed white light interferometry demodulation technologies rely on high-tuning-speed laser sources,but the bandwidth of such light sources is narrow,which limits the measurement range.At the same time,this type of technology requires a large amount of calculations and sometimes requires offline signal processing.Various laser interference demodulation algorithms have been proposed to extract dynamic signals from EFPI sensors.However,these demodulation techniques will collapse if the EFPI cavity length changes significantly since the cavity length and laser wavelengths must be strictly matched to obtain orthogonal signals.In this article,a correction symmetrical demodulation method for the measurement of static/dynamic composite signals is proposed.Static/dynamic composite signal demodulation is experimentally demonstrated.Methods The change in sensor cavity length is judged by the direct current component of the output signal of the symmetrical demodulation method.Then,the output signal is divided into stable segments and abrupt segments.The measurand is then re-demodulated segment by segment to improve the demodulation accuracy of the dynamic component.Phase differences calculated before and after the abrupt segment are used to compensate for the change in cavity length,and the demodulation accuracy of static components is improved.The process of static/dynamic composite signal demodulation is as follows:1)the preliminary demodulation signal df is recovered through Eq.(11).2)the signal df is divided into stable segments and abrupt segments.3)the phase differenceδfor each stable segment is calculated.4)the average value ofδbefore and after the abrupt segment is used as the phase difference of the abrupt segment to re-demodulate the signal.Eq.(4)is then used to calculate cavity lengths before and after the abrupt segment,and the cavity length change of the abrupt segment is calibrated.5)the measurand of each stable segment is re-demodulated and combined with the calibrated abrupt segment demodulation signals to obtain the complete output signal ds.Results and Discussions Static/dynamic composite signals can be demodulated by the proposed demodulation method,which is experimentally demonstrated,as shown in Fig.4.The cavity length change of the c-sym in Fig.4(a)is 50.86μm,which is consistent with the cavity length change measured by the white light interference demodulation algorithm.The measurement error of the static component is 2.07%.Figures 4(b)-(e)show that the dynamic component of the c-sym remains consistent despite the cavity length changes significantly.The peak-to-peak amplitudes are 408.33 nm,407.58 nm,and 402.17 nm.The amplitude variation is 1.53%.The power spectrum of the dynamic component of the c-sym is plotted in Fig.5.The frequency is 100 Hz,which is consistent with the frequency of the input signal.The proposed demodulation method can be performed normally even if the cavity length changes up to 100μm,as shown in Fig.6.The frequency range of the proposed demodulation method is consistent with that of the symmetrical demodulation method and is not limited by the demodulation principle.The frequency range of the demodulator is only limited by the sampling frequency of the analog-to-digital converter and the bandwidth of electronic devices such as photodiodes.The analog-to-digital converter of the demodulator has a sampling frequency of 200 kHz.According to the Nyquist sampling theorem,the maximum frequency of the signal which the demodulator can demodulate is 100 kHz.Conclusions In conclusion,a correction symmetrical demodulation method for the measurement of static/dynamic composite signals is proposed.The demodulation capability of the demodulator to static/dynamic composite signals is experimentally investigated.The measurement of a cavity length change with an amplitude of 100μm is achieved.The measurement error is about 2%for large changes in cavity length.The technique is applicable to static/dynamic composite signals applied on sensors with different cavity lengths.
作者 贾景善 Jia Jingshan(College of Communication and Information Technology,Xi'an University of Science and Technology,Xi'an 710054,Shaanxi,China)
出处 《光学学报》 EI CAS CSCD 北大核心 2023年第23期39-44,共6页 Acta Optica Sinica
基金 国家自然科学基金青年科学基金(62305265) 陕西省自然科学基础研究计划(2022JQ-613)。
关键词 光纤光学 光纤传感技术 激光干涉测量 相位解调 外腔式Fabry-Perot干涉仪 fiber optics fiber sensing technique laser interferometry phase demodulation extrinsic Fabry-Perot interferometer
  • 相关文献

参考文献6

二级参考文献34

共引文献69

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部