期刊文献+

γ能谱法测量分析阀门中铀滞留量技术研究

Study on Holdup Measurement of Uranium in Valve byγ-ray Spectrometry
下载PDF
导出
摘要 定量测量工艺设备中的滞留量是核设施核材料测量的技术难点之一,对辐射防护、核材料临界安全和核材料闭合衡算具有重要意义。在核材料工艺生产线上,阀门与管道的连接方式不利于取样,因此,非破坏性分析方法更适合用于开展阀门中滞留量的测量。本文采用无源效率刻度,针对球阀和蝶阀这两种最常见的阀门,建立了探测器全能峰绝对探测效率分析模型。运用坐标变换方法,实现了阀门分析模型的快速建立。在实验室条件下采用标准点源和铀样品进行了初步验证,铀样品中235 U含量的测量分析结果和标称值的相对偏差小于15%。坐标变换方法可快速准确地建立各种类型阀门的分析模型,为测量分析模型的建立提供了简便易行的解决方案。 During the production and operation of some bulk handling facilities,nuclear material deposits remaining after cleaning in and about process equipment,interconnecting piping,filters and adjacent work area or equipment,which is called holdup.In order to meet the requirements of nuclear material accounting management,the physical inventory of nuclear materials shall be carried out according to the specified frequency,and the amount of nuclear materials shall be the measured value.Quantitative measurement of holdup in equipment is one of the technical difficulties in nuclear material measurement for nuclear facilities.Holdup measurement is important for radiation protection,critical safety and nuclear material management.The valve is a key component to control the material transfer in the process of nuclear material production.The valve is welded to pipe,which is not conducive to sampling.In this paper,mass of uranium in the valve was measured byγ-ray spectroscopy.It is necessary to study absolute detection efficiencies of the detector for known source distribution.Firstly,the passive efficiency calibration was selected to simulate the absolute detection efficiencies.Analysis models consist of detector model and valve models,they were placed under the same observation system by the transforming coordinate method.Analysis models of detector and valves were built based on information of the detector and design drawing of the valves.Two point sources,57 Co and 137 Cs,were used to verify the model.Under the combination of different crystal radius and length parameters,the absolute detection efficiencies for full-energyγ-rays peak were simulated.The crystal parameters of the LaBr 3 detector were adjusted.The root mean square of the relative deviation between the simulation results and the experimental results was calculated.The crystal parameters with the smallest root mean square are the best parameters.The relative deviation between the experimental results and Monte Carlo simulation results for point sources is within 5%.The standard uranium sample was used to carry out experiments.The count rate of characteristicγ-ray was measured by the LaBr 3 detector.The absolute detection efficiencies were simulated by the analysis model.The holdup was calculated according to the relationship between count rate of characteristicγ-ray and the mass of uranium.The results show that the relative deviation between the measured results and the reference values of uranium mass is within 15%.The feasibility of the method for measuring the uranium holdup in the valves is preliminarily confirmed by the experiments.The transforming coordinate,a simple and easy solution,by which the analysis model can be quickly and accurately built.
作者 王晶 何丽霞 邵婕文 李育蓉 WANG Jing;HE Lixia;SHAO Jiewen;LI Yurong(Department of Radiochemistry,China Institute of Atomic Energy,Beijing 102413,China)
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2024年第2期489-497,共9页 Atomic Energy Science and Technology
关键词 滞留量 阀门 蒙特卡罗模拟 Γ能谱法 holdup valve Monte Carlo simulation γ-ray spectrometry
  • 相关文献

参考文献11

二级参考文献38

  • 1陆向东,田东风,解东.双层介质核材料的γ特征谱分析[J].核技术,2004,27(11):814-817. 被引量:4
  • 2朱荣保,金惠民,谭亚军,王瑞宏,郏惠忠,刘建刚,贾向军,章泽甫,杨留成.钚处理设备物料滞留量监测仪[J].原子能科学技术,1994,28(4):316-323. 被引量:3
  • 3张斌全,马吉增,程建平,刘立业,毛永.蒙特卡罗方法计算用于低能光子测量的高纯锗探测器的效率[J].核电子学与探测技术,2005,25(3):274-277. 被引量:26
  • 4复旦大学 清华大学 北京大学.原子核物理实验方法[M].北京:原子能出版社,1997.93-96,109-117,301-304.
  • 5Alonso M,et al. Monte Carlo estimation of absorbed dose to organs in computed tomography[J].Health Phys,2002,82(2):233.
  • 6Stabin MG,et al.Photon specific absorbed fractions culculated in the trunk of an adult male voxel-based phantom[J]. Health Phys,2002,82(1):21.
  • 7Borisov N,. et al.A new graphical user interface for fast construction of computation phantoms and mcnp calculations:application to calibration of in vivo measurement systems[J]. Health Phys,2002,83(2):272.
  • 8Bozkurt A, et al Fluence-to-dose conversion coefficients from monoenergetic neutrons below 20 MeV based on the VIP-Man anatomical model[J]. Phys Med Biol,2000,(45):3059.
  • 9Moens L, et al Calculation of the absolute peak efficiency of gamma-ray detectors for different counting geometries[J]. Nucl Instrum Methods,1981,187:451.
  • 10Moens L, et al Calculation of the peak efficiency of high-purity Germanium detectors[J]. Int J Appl Radiat Isot,34(8):1085.

共引文献63

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部