摘要
对于柔直、轨道交通等领域用的直流支撑电容器而言,交直流叠加的试验验证更符合实际工况所需。电容制造厂家如何利用现有试验设备,搭建交直流叠加试验所需的试验平台,重点在于对交、直流电源的隔离保护。本文在介绍交流、直流独立试验回路及交直流叠加试验回路原理的基础上,明确了隔直电容和隔交电感、放电电阻的参数选择原则,为各电容厂家利用厂内现有设备,尽最大可能降低设备成本的前提下,提供一种直流支撑电容交直流叠加试验平台搭建的思路和方法。
For DC-link capacitor used in such fields as flexible and rail transit,the test verification of AC/DC superposition is more in line with the need of actual condition.The focus of how the capacitor manufacturers can utilize existing testing equipment to set up a testing platform for AC/DC superimposed testing is in the isolation protection of AC and DC power sources.On the basis of introducing the principles of AC and DC independent test circuits and AC/DC superimposed test circuits,the parameter selection principles of DC isolation capacitors,AC isolation inductors and discharge resistors are clearly defined.It provides a train of thought and method for setting up a DC-link capacitor AC/DC superimposed test platform for capacitor manufacturers to utilize existing equipment in the factory and minimize equipment costs.
作者
邓光昭
黄葵
王文宝
DENG Guangzhao;HUANG Kui;WANG Wenbao(Jiashan Sunking Power Electronic Capacitor Co.,Ltd.,Zehjiang Jiashan 314100,China)
出处
《电力电容器与无功补偿》
2024年第1期140-144,共5页
Power Capacitor & Reactive Power Compensation
基金
国家重点研发计划(2021YFB2401504)。
关键词
直流支撑电容
隔直电容
隔交电感
放电电阻
耐久试验
破坏试验
DC-link capacitor
blocking capacitor
isolate alternating inductance
discharge resistance
endurance test between terminals
destruction test