主要介绍了S钢集团125 t/h干熄焦提升机电气控制系统,并对经常出现的控制信号故障进行分析总结,提出了有效的故障处理策略,使干熄焦率得到明显提升,确保干熄焦生产和蒸汽发电的稳定运行。
This paper mainly introduces the electric control system of 125 t/h CDQ crane in Sangang Group,and analyzes causes and solutions of signal failure,which helps to dramatically improve the CDQ capacity.Consequently,stable CDQ production and power gene ration by steam is ensured.