期刊文献+

基于光纤传感的生命体征监测技术研究现状

Research Status of Vital Signs Monitoring Technology Based on Optical Fiber Sensing
下载PDF
导出
摘要 传统的接触式生命体征监测仪器存在一些使用上的限制,如不便于操作和需要频繁更换传感器等问题。近年来,科研工作者一直致力于研究和探索基于光纤传感的生命体征监测方法,旨在寻求一种成本低廉、可靠性高且适用范围广泛的监测方法。基于光纤传感的生命体征监测方法在心率、呼吸、体温、血压及血糖等方面取得了显著的研究进展。这种基于光纤传感的监测方法可以实现非接触式监测,无须直接接触人体,从而减少对人体的不适感,其有望在临床医学和健康管理等领域得到更广泛的应用,并为人类健康提供更精准和舒适的监测和预警手段。 There are some limitations in the use of traditional contact vital signs monitoring instruments,such as inconvenient operation and frequent replacement of sensors.In recent years,researchers have been devoted to the research and exploration of vital signs monitoring methods based on optical fiber sensing,aiming at finding a monitoring method with low-cost,high-reliability and wide scope of application.The vital signs monitoring method based on optical fiber sensing has made remarkable research progress in heart rate,respiration,body temperature,blood pressure and blood sugar.This monitoring method based on optical fiber sensing can realize non-contact monitoring without direct contact with human body,thus reducing the discomfort to the objects.It is expected to be widely used in the fields of clinical medicine and health management,and provide more accurate and comfortable monitoring and early warning means for human health.
作者 杨义龙 冯逸飞 王勇 刘意 朱刘凤 何颖 YANG Yilong;FENG Yifei;WANG Yong;LIU Yi;ZHU Liufeng;HE Ying(School of Health Science and Engineering,University of Shanghai for Science and Technology,Shanghai 200093,China;Department of Marine Biomedicine and Polar Medicine,Naval Specialty Medical Center,Shanghai 200433,China)
出处 《医学综述》 CAS 2024年第3期339-344,共6页 Medical Recapitulate
基金 海军特色医学中心青年科技创新人才项目(21TPQN0803)。
关键词 生命体征监测 光纤传感 非接触式 Vital sign monitoring Optical fiber sensing Non-contact
  • 相关文献

参考文献5

二级参考文献24

  • 1闫庆广,吴宝明,卓豫,朱新建,冯正权,黄华.穿戴式单兵生命监测系统研究的进展[J].中国医疗器械杂志,2006,30(5):345-348. 被引量:13
  • 2赵捷,华玫.由单通道心电提取呼吸信息的算法[J].生物医学工程学杂志,2006,23(6):1202-1205. 被引量:6
  • 3孙恩昌,李于衡,张冬英,易克初.自适应变步长LMS滤波算法及分析[J].系统仿真学报,2007,19(14):3172-3175. 被引量:49
  • 4Yassar M, Mumtaz A. Respiratory waveform facilitating recognition of hiccupinduced electrocardiographic artifacts [J]. International Journal of Cardiology (S0167-5273), 2007, 118(3): 416-417.
  • 5Schrader M, Zywietz C, Einem Y, et al. Detection of sleep apnea in signal channel ECGs from the physionet data base [J]. Computers in Cardiology (S0276-6574), 2000: 263-266.
  • 6Eduardo G- Jose M V, Pablo L. Detection of decreases in the amplitude fluctuation of pulse photoplethysmography signal as indication of obstructive sleep apnea syndrome in children [J]. Biomedical Signal Processing and Control (S1746-8094), 2008, 3(3): 267-277.
  • 7Inan O, Kovacs G, Giovangrandi L. Evaluating the lower-body electromyogram signal acquired from the feet as a noise reference for standing ballistocardiogram measurements [J]. Information Technology in Biomedicine (S 1089-7771), 2010, 14(5): 1188-1196.
  • 8Omata K, Hanakawa T, Morimoto M. Influence of cardiac and respiratory artifacts on the relationship between spontaneous EEG and fMR/signals [J]. Clinical Neurophysiology (S1388-2457), 2010, 121(1): 216-217.
  • 9Jingjing J, Xu W, Yingnan W, et al. Pseudo-period segment of ballstocardiogram based on joint time-frequency analysis [C]// Intelligent Computing and Intelligent Systems, 2009: 467-470.
  • 10Coifman R, Donoho D, Antoniadis A, et al. Translation-invariant denoising [J]. Wavelets and Statistics (S0387-9456), 1995, 3(4): 125-150.