摘要
以660MW超超临界塔式锅炉为例,对塔式锅炉炉内气气换热器扩容改造方案进行了介绍,对气气换热器布置特点、性能核算要点进行了介绍。
Taking the 660 MW ultra-supercritical Tower boiler as an object of study,The expansion and transformation scheme of Gas-air Heat Exchanger in Tower boiler is introduced,The characteristics of Gas-air Heat Exchange layout and key points of performance calculation are introduced.
作者
曲道志
QU Daozhi(Harbin Boiler Company Limited,Harbin 150046,China)
出处
《锅炉制造》
2024年第1期19-20,23,共3页
Boiler Manufacturing
关键词
扩容改造
热源
气气换热器
extension and renovation
heat source
flue Gas-air Heat Exchanger