摘要
市政污水系统内污染元素较多,为实现对污水中氮元素等污染物质的去除,文中利用短程反硝化工艺进行处理。结果表明,反应器、接种污泥的选择,直接影响污水处理效果,并可识别影响短程反硝化工艺的因素,改善工艺条件,提高污水处理效果。
There are many pollutants in the municipal sewage system.In order to achieve the removal of nitrogen and other pollutants in the sewage,a short-range denitrification process is used for treatment in this article.The research results indicate that the selection of reactors and inoculated sludge directly affects the sewage treatment efficiency,and can identify the factors that affect the short-range denitrification process,improve process conditions,and enhance sewage treatment efficiency.
作者
黄长在
Huang Changzai(Fuzhou Gongchuang Environmental Protection Technology Co.Ltd.,Fuzhou,Fujian 350001)
出处
《江西建材》
2023年第11期375-376,379,共3页
Jiangxi Building Materials
关键词
污水处理
短程反硝化
厌氧氨氧化
接种污泥
Sewage treatment
Short range denitrification
Anaerobic ammonia oxidation
Inoculated sludge