某五星级酒店扩建工程项目地下室顶板防水设计采用2.0 mm厚非固化橡胶沥青防水涂料+4.0 mm厚耐根穿刺自粘聚合物改性沥青防水卷材的涂卷复合方案;屋面防水设计采用2.0 mm厚非固化橡胶沥青防水涂料+1.5 mm厚无胎自粘高分子膜基改性沥青防水卷材的涂卷复合方案,并对种植顶板变形缝、后浇带、屋面女儿墙、出屋面管道等细部节点部位做了重点处理,消除了窜水隐患,防水效果良好。
The waterproofing design of the basement top plate of a five-star hotel expansion project adopts a composite scheme of 2.0 mm thick non-solidified rubber asphalt waterproofing coating+4.0 mm thick root resistant self-adhesive polymer modified bitumen waterproofing membrane;while the roof waterproofing design adopts a combined system of 2.0 mm thick non-solidified rubber asphalt waterproofing coating+1.5 mm thick carrierless self-adhesive polymer film reinforced modified bitumen waterproofing membrane.Treatment for details has been carried out,such as deformation joints of the planted roof,the post-cast strip,roof parapet wall,and the pipes out of roof,to eliminate the risk of water channeling,and good waterproofing effect has been achieved.
作者
程周模
Cheng Zhoumo(Shenzhen Joaboa Technology Co.,Ltd.,Shenzhen,Guangdong518049,China)
出处
《中国建筑防水》
2024年第2期34-38,共5页
China Building Waterproofing
关键词
地下室顶板
非固化橡胶沥青防水涂料
耐根穿刺自粘聚合物改性沥青防水卷材
涂卷复合
basement top plate
non-solidified rubber modified asphalt waterproofing coating
root resistant polymer modified bitumen self-adhesive waterproofing membrane
composite of coating and membrane