摘要 通过整理现阶段消防控制室供配电设计中经常出现的问题,包括双电源切换开关数量不合理、消防电源配电箱未设置消防电源监控、以及消防控制室未设置消防备用照明等,提出科学合理的解决方案,探究以安全为先的工厂消防控制室的供配电设计要点,保障消防设施在各种工况下均能处于安全稳定的状态,提高消防控制室供配电设计方案的安全性、可靠性、科学性。 By summarizing the common problems in the current design of power supply and distribution in fire control center,including unreasonable number of automatic transfer switching equipment,fire power distribution box not equipped with fire power monitoring,and the fire control room not equipped with fire backup lighting,etc.,this paper proposed scientific and reasonable solutions,explored the key points of power supply and distribution design for factory fire control center with safety as the priority,which ensured the fire protection facilities in a safe and stable state under various working conditions,improved the safety,reliability,and scientificity of the power supply and the distribution design scheme of the fire control center.
作者 郭猛 Guo Meng(SINOPEC Ningbo Engineering Co.,Ltd.,Ningbo 315103)
出处 《大氮肥》 CAS 2024年第1期67-69,72,共4页 Large Scale Nitrogenous Fertilizer Industry
关键词 消防控制室 供配电设计 安全稳定 fire control center power supply and distribution design safety and reliability