期刊文献+

气相色谱-质谱法测定地表水中的多氯联苯

Determination of Polychlorinated Biphenyls in Surface Water by GasChromatography-Mass Spectrometry
下载PDF
导出
摘要 本文建立了气相色谱质谱法(GCMS)检测地表水中18种多氯联苯含量的方法,通过液萃取法萃取样品中的多氯联苯。萃取液经过脱水、浓缩、净化定容后使用GCMS进行分离和检测。本文通过内标法定量,用同一方法比较四种水质(矿泉水、自来水、青山湖水和养殖场尾水)的检出限、回收率、精密度、标准工作曲线的相关系数等指标。18种多氯联苯在20~500μg/L范围内线性关系良好,相关系数均大于0.995。方法检出限为0.0006~0.0015μg/L,定量限为0.0024~0.0060μg/L。实验结果表明,该方法灵敏度好,选择性高,定性定量准确可靠,适合多种地表水中多氯联苯的检测。 A gas chromatography-mass spectrometry(GCMS)method was developed for the determination of 18 polychlorinated biphenyls in surface water.Polychlorinated biphenyls in samples were extracted by liquid-liquid extraction method.After dehydration,concentration,purification and constant volume,the extracting solution was separated and detected by GCMS。The linearity of 18 PCBs was good in the range of 20~500μg/L,the correlation coefficient was greater than 0.995.The limit of detection was 0.0006~0.0015μg/L,and the limit of quantification was 0.0024~0.0060μg/L.The experimental results show that this method has good sensitivity,high repeatability,and can accurately detect the contents of 18 PCBs in surface water.
作者 闻超 Wen Chao(Nanchang Environmental Protection Technology Service Center Co.,LTD.,Nanchang Jiangxi 330000,China)
出处 《江西化工》 CAS 2024年第1期27-30,共4页 Jiangxi Chemical Industry
关键词 多氯联苯 地表水 气相色谱质谱法 polychlorinated biphenyls surface water gas chromatography-mass spectrometry
  • 相关文献

参考文献8

二级参考文献90

共引文献119

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部