桡骨远端骨折夹板外固定的骨折缝应力预测

Prediction of Fracture Suture Stress for Distal Radius Fractures Fixed by the Splint
下载PDF
导出
摘要 目的 运用静力学分析、试验设计法以及布谷鸟-支持向量机预测建立关于C1_1、C2_1、C3_1型桡骨远端骨折夹板固定不同厚度压垫下骨折缝应力关系的数学模型。方法 在CT影像中获得前臂中各个组织的形状,建立对应的实体模型,进行降噪、装配等过程实现建模;在Workbench中根据实验测定的载荷数据对模型施加载荷,获得一种情况下的骨组织力学情况;再通过试验设计法对多种施加载荷情况下的骨组织力学情况进行模拟;最后,通过布谷鸟改进支持向量回归预测,获得关于各骨折类型的数学模型。结果 对B曲面划分的12个压垫固定位置施加载荷,通过试验设计法对460个样本在Workbench中DOE模块中进行求解,460个样本中随机抽取400个作为训练集得到数学模型,用剩余60个样本作为测试集与数学模型预测结果进行对比,即可建立高精度的有关夹板固定中压垫固定位置上不同载荷和骨折缝处载荷情况的数学模型。通过已知压垫固定区域施加不同厚度压垫的固定力对骨折缝应力的预测,预测值与仿真值进行对比模型预测精度最高达到99.66%,最低达到95.653%。从精度上分析,压垫载荷与骨折缝处载荷存在模糊的数学关系,即支持向量机预测模型有效。结论 通过研究压垫固定作用方式和压垫固定力对骨折缝的影响,有利于传统固定夹板与现代科学技术相结合,为临床骨折治疗桡骨远端骨折时固定器的选择和外固定器械设计提供参考。 Objective To establish a mathematical model for fracture suture load relationship of C1_1,C2_1,C3_1 type distal radius fractures fixed by the splint with different pad thicknesses by using static analysis,design of experiment(DOE) and cuckoo-support vector machine prediction.Methods The shape of each tissue in the forearm was obtained from CT images,the corresponding solid models were established,and the modeling was achieved by noise reduction,assembly processes.The mechanical situation of bone tissues under one condition was obtained by applying load to the model according to load data measured by the Workbench.Then through the DOE method,the mechanical conditions of bone tissues under various conditions of the applied load were simulated.Finally,the mathematical models for various fracture types were obtained by cuckoo search-support vector regression(CS-SVR) prediction.Results The load was applied to the fixed position of 12 pressure pads divided by the B surface,and 460 samples were solved in DOE module in Workbench by the DOE method,and 400 of the 460 samples were randomly selected as the training set to obtain the mathematical model.The remaining 60 samples were used as the test set for comparison with prediction result of the mathematical model.The high precision mathematical models for different loads on the fixed position of the splint and the load at fracture suture could be established.The highest prediction accuracy of the model was 99.659%,and the lowest was 95.653%.From the accuracy analysis,there was a fuzzy mathematical relationship between the pad load and fracture suture load,indicating that the support vector machine prediction model was effective.Conclusions The study on the effect of pressure splint fixation mode and pressure splint stress on fracture suture is beneficial for the combination of traditional fixation splint and modern science and technology,and it can provide references for the selection of fixators and the design of external fixation devices in clinical treatment of distal radius fractures.
作者 王聪轩 萨日娜 包呼和 WANG Congxuan;SA Rina;BAO Huhe(College of Mechanical Engineering,Inner Mongolia University of Technology,Hohhot 010051,China;Department of Orthopaedic Trauma,Inner Mongolia People’s Hospital,Hohhot 010017,China)
出处 《医用生物力学》 CAS CSCD 北大核心 2023年第6期1179-1185,共7页 Journal of Medical Biomechanics
基金 国家自然科学基金项目(51765052) 内蒙古自然科学基金项目(2020LH05009) 内蒙古自治区直属高校基本科研业务费项目(JY20220282)。
关键词 桡骨远端骨折 夹板固定 压垫 试验设计法 布谷鸟-支持向量机预测 distal radius fracture splint fixation pressure pad design of experiment cuckoo-support vector machine prediction
  • 相关文献

参考文献10

二级参考文献64

共引文献38

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部