摘要 某企业根据生产运行情况采用高质量的阳极进行开槽工业试验,试验实施后电解槽运行向好,阳极运行过程中保持了形状稳定,残极形状规则,炭渣量降低2 kg/t·Al;主要经济技术指标改善,电解槽平均电压降低7 mV,电流效率提升0.11%,直流电耗降低40 kWh/t·Al。 According to the operation conditions of a certain enterprise,high-quality anodes were used for slotting industrial test.After the test,the electrolytic cell ran well.During the operation of the anode,the shape was stable,the shape of the residue was regular,and the amount of carbon slag was reduced by 2 kg/t·Al.The main economic and technical indicators are improved,the average voltage of the electrolytic cell is reduced by 7 mV,the current efficiency is increased by 0.11%,and the DC power consumption is reduced by 40 kWh/t·Al.
作者 陈新群 CHEN Xinqun(Lanzhou Aluminum Co.Ltd.,Lanzhou 730060,China)
出处 《甘肃冶金》 2024年第1期84-86,共3页 Gansu Metallurgy
关键词 铝电解 开槽阳极 炭渣量 电解槽电压 aluminum electrolysis slotted anode amount of carbon residue electrolytic cell voltage
  • 相关文献

参考文献3

二级参考文献9

  • 1[1]Xiangwen Wang.Development and deployment of slotted anode technology at alcoa[J].Light metals,2007.
  • 2[2]S.C.Tandon.Energy Saving in Hindalco's Aluminium Smelter[J].Light Metals,2005.
  • 3[3]H.P.Dias,R.Raposo de Moura.The Use of Tranversal Slot Anodes at Albras Smelter[J].Light Metals,2005.
  • 4[4]Kotil Aldstedt Rye.The Effect of Implementing Slotted Anodes on Some Key Operational Parameters of a PB-line[J].Light Metals,2007.
  • 5[5]Jean-Jacques Grunspan.Slot Cutting in anodes[J].Light metals,2007.
  • 6[6]Markus W.Meier.Production and Performance of Slotted Anodes[J].Light metals,2007.
  • 7彭建平,田应甫,冯乃祥,王耀武,王紫千.新型阴极结构电解槽铝电解试验[J].材料与冶金学报,2009,8(3):165-167. 被引量:22
  • 8李贺松,曹曦,田应甫.低能耗下铝电解槽阳极结构的优化[J].中国有色金属学报,2012,22(10):2960-2969. 被引量:15
  • 9杨帅,张红亮,徐宇杰,张翮辉,邹忠,李劼,赖延清.铝电解槽预焙阳极开槽对气泡排出的影响[J].中南大学学报(自然科学版),2012,43(12):4617-4625. 被引量:8