期刊文献+

腓骨肌皮瓣穿支血管定位导板的临床应用

Clinical application of perforator vessel location guide plate for fibular musculocutaneous flaps
下载PDF
导出
摘要 目的 探讨3D打印固定式定位导板在腓骨肌皮瓣穿支血管的精准定位方法并评价其应用效果。方法 本研究已通过单位伦理委员会审查批准,并获得患者知情同意。选取2019年5月至2022年10月就诊于新疆医科大学第一附属医院口腔颌面外科由于颌骨缺损需行腓骨肌穿支皮瓣游离移植修复的患者14例。导板组(7例)采用CTA结合Mimics软件三维重建患者双下肢并定位穿支血管位置,数字化设计腓骨肌皮瓣穿支血管定位导板,将导板的两端设计为固定端,上方一端固定于膝关节,下方一端固定于踝关节,3D打印完成导板;对照组(7例)采用常规手持式多普勒进行术前定位。比较两组皮瓣制取时间、术中出血量、住院时间、定位穿支血管的差异、术后并发症出现情况、术后供区外形满意度及下肢功能评定量表(lower extremity functional scale,LEFS)。采用SPSS 25.0软件包对数据进行统计学分析。结果 导板组的制取皮瓣时间、术中出血量、住院时间、穿支血管定位及术后供区外形满意度均优于对照组,差异有统计学意义(P<0.05),术后皮瓣并发症、LEFS评分差异无统计学意义(P>0.05)。结论 基于3D打印技术的腓骨肌皮瓣穿支血管固定式定位导板的定位准确性更好,采用膝关节和踝关节固定点,能更有效地稳定导板位置,避免软组织偏移,提高了定位精准度,值得临床推广。 Objective Based on 3D printing technology,explore the precision of a perforator vessel location guide plate for fibular musculocutaneous flaps before the transplantation of fibular osteocutaneous flaps and evaluate its appli-cation effects.Methods This study was reviewed and approved by the ethics committee,and informed consent was obtained from the patients.From May 2019 to October 2022,14 patients with jaw defects who needed to undergo fibular perforator flap transplantation at the First Affiliated Hospital of Xinjiang Medical University were selected.For the sev-en patients in the guide plate group,CTA was combined with Mimics software to reconstruct both lower limbs,and the perforator vessel positioning guide for locating perforator vessels was designed;the two ends of the guide plate were de-signed as fixed ends,with the upper end fixed to the knee joint and the lower end fixed to the ankle joint,and the guide plate was fabricated by a 3D printer.For the seven patients in the control group,a conventional handheld Doppler probe was used for perforator vessel location.The average operation time,bleeding volume,recovery time,deviation of perfora-tor vessel location,postoperative flap-related complications,postoperative donor site shape satisfaction,and lower ex-tremity functional scale(LEFS)score were recorded.SPSS 25.0 software was used for statistical analysis.Results The average operation time,bleeding volume,recovery time,deviation of perforator vessel location and postoperative donor site shape satisfaction were significantly better in the guide plate group than in the control group(P<0.05);moreover,the differences in postoperative flap-related complications and LEFS scores were not statistically significant(P>0.05).Conclusion Based on 3D printing technology,fibular musculocutaneous flap perforator vessels can be more accurately located using a guide plate and the knee and ankle as fixed points,and this method can effectively stabilize the guide position,prevent soft tissue offset,and improve positioning accuracy and thus deserves to be generalized.
作者 许立明 张一博 乃吉拜·莫敏 李娇阳 凌彬 XU Liming;ZHANG Yibo;NAIJIBAI·Moming;LI Jiaoyang;LING Bin(Department of Oral and Maxillofacial Oncology,the First Affiliated Hospital of Xinjiang Medical University(the Affiliated Stomatology Hospital of Xinjiang Medical University)&Stomatology Disease Institute of Xinjiang Uyghur Autonomous Region,Urumqi 830054,China)
出处 《口腔疾病防治》 2024年第4期280-286,共7页 Journal of Prevention and Treatment for Stomatological Diseases
基金 新疆维吾尔自治区区域协同创新专项(科技援疆计划)(2020E02130)。
关键词 腓骨肌皮瓣 穿支血管 固定式定位导板 数字化设计 3D打印 CT血管造影 颌骨缺损 重建功能性外科 fibular osteocutaneous flap perforator vessel fixed⁃positioning guide plate digital design 3D⁃printing computed tomography angiography jaw defect reconstructive functional surgery
  • 相关文献

参考文献1

共引文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部